4
Precision Edge
SY100EL29V
Micrel, Inc.
M9999-031306
hbwhelp@micrel.com or (408) 955-1690
TA = –40
°CTA = 0°CTA = +25°CTA = +85°C
Symbol
Parameter
Min.
Max.
Min.
Max.
Min.
Typ.
Max.
Min.
Max.
Unit
f
MAX
Max. Toggle Frequency
1.1
—
1.1
—
1.1
—
1.1
—
GHz
t
PD
Propagation Delay
CLK
480
680
490
690
500
—
700
520
720
ps
to Output
S, R
450
670
450
670
450
—
670
450
670
t
S
Set-Up Time, D
200
—
200
—
200
—
200
—
ps
t
H
Hold Time, D
150
—
150
—
150
—
150
—
ps
t
RR
Reset Recovery Time
300
—
300
—
300
—
300
—
ps
t
PW
Minimum Pulse Width
400
—
400
—
400
—
400
—
ps
CLK, Set, Reset
V
CMR
Common Mode Range(1)
V
<500mV
–2.0
–0.4
–2.1
–0.4
–2.1
—
–0.4
–2.1
–0.4
≥500mV
–1.8
–0.4
–1.9
–0.4
–1.9
—
–0.4
–1.9
–0.4
V
PP (AC)
Minimum Input Swing(2)
150
—
150
—
150
—
150
—
mV
t
r
Output Rise/Fall Time Q
280
550
280
550
280
330
550
280
550
ps
t
f
(20–80%)
AC ELECTRICAL CHARACTERISTICS
V
EE = –3.0V to +5.5V; VCC = GND
Notes:
1. VCMR is referenced to the most positive side of the differential input signal. Normal operation is obtained when the input signals are within the VCMR range
and the input swing is greater than VPP(Min.) and <1V. The lower end of the VCMR range varies 1:1 with VEE. The numbers in the spec table assume
a nominal VEE = –3.3V. Note for PECL operation, the VCMR(Min) will be fixed at 3.3V – |VCMR(Min)|.