Specifications
3
RATINGS
Relay Output
Item
SRT
P
-ROC08, SRT
P
-ROC16
Applicable relay
Rated load
Rated carry current
Max. contact voltage
Max. contact current
Max. switching capacity
Min. permissible load
(See Note 2)
Life expectancy
G6D-1A (one for each output point)
3 A at 250 VAC, 3 A at 30 VDC (resistive load)
3 A (See Note 1)
250 VAC, 30 VDC
3 A
730 VA (AC), 90 W (DC)
10 mA at 5 VDC
Electrical:
100,000 operations min. (rated load, at 1,800 operations/h)
Mechanical: 20,000,000 operations min. (at 18,000 operations/h)
Note: 1.
The maximum permissible current of COM0 to COM7 is 3 A.
This value fulfills the P reference value of opening/closing at a rate of 120 times per min (ambient operating environment and
determination criteria according to JIS C5442).
2.
Power MOSFET Output
Item
SRT
P
-ROF08, SRT
P
-ROF16
Applicable relay
Load voltage
Load current
Inrush current
G3DZ--2R6PL (one for each output point)
3 to 264 VAC, 3 to 125 VDC
100
μ
A to 0.3 A
6 A (10 ms)
3
CHARACTERISTICS
Power supply voltage
Current consumption
(See Note)
Connection method
24 VDC
+10%
/
--15%
350 mA max. at 24 VDC
Multi-drop method and T-branch method
Secondary branches cannot be connected to T-branch lines.
8-point Units: 16 per Master
16-point Units: 8 per Master
2,000 VAC for 1 min (1 mA sensing current) between all output terminals and power supply,
between communication terminals, and between contacts of different polarities
500 VAC for 1 min (1 mA sensing current) between all output terminals and power supply,
between communication terminals, and between all power supply terminals and
communications terminals
Power supply normal:
±
600 V for 10 min with a pulse width of 100 ns to 1
μ
s
Power supply common:
±
1,500 V for 10 min with a pulse width of 100 ns to 1
μ
s
10 to 55 Hz, 0.75--mm double amplitude
Malfunction: 100 m/s
2
Destruction: 300 m/s
2
No damage when 50 N pull load was applied for 10 s in all directions
No damage when 50 N pull load was applied for 10 s
0.6 to 1.18 N
:
m
Operating:
0
°
C to 55
°
C (32
°
to 131
°
F) with no icing or condensation
Storage:
--20
°
C to 65
°
C (--4
°
to 149
°
F) with no icing or condensation
Operating:
35% to 85%
8-point models: 145 g max., 16-point models: 240 g max.
UL 508, CSA C22.2 No. 14
Connecting units
Dielectric strength
Noise immunity
Vibration resistance
Shock resistance
Mounting strength
Terminal strength
Screw tightening torque
Ambient temperature
Ambient humidity
Weight
Approved standards
Note: The above current consumption is a value with all the points turned ON including the current consumption of the G6D coil for the
Remote Output Terminal.