S82H
S82H
2
Model Number Legend
1. Power Factor Correction
None:No
P:
Yes
2. Output Capacity
100: 100 W
150: 150 W
300: 300 W
600: 600 W
3. Output Voltage
05: 5 V
12: 12 V
15: 15 V
24: 24 V
S82H -
1
3
2
Conversion Table
Conventional model
New model
S82H-3005
S82H-10005
S82H-3012
S82H-10012
S82H-3024
S82H-10024
S82F-1512
S82H-15012
S82F-1524
S82H-15024
Specifications
Ratings/Characteristics
Item
PFC
No
Yes
100 W
150 W
100 W
150 W
300 W
600 W
Efficiency
70% to 86% (depending on the model)
Life expectancy (see note 1.)
10 years min. in standard installation conditions at 40
°C at the rated input with 50% load.
Input
Voltage
100 to 120 VAC/200 to
240 VAC (selectable) (85 to
132 VAC/170 to 264 VAC)
100 to 240 VAC (85 to 264 VAC)
Frequency
47 to 450 Hz
47 to 63 Hz
Current
at 100-V input
2.5 A max.
4 A max.
1.7 A max.
2.5 A max.
5 A max.
10 A max.
at 200-V input
1.5 A max.
2.5 A max.
0.85 A max.
1.3 A max.
2.5 A max.
5 A max.
Leakage current
at 100-V input
0.5 mA max.
0.75 mA max.
1 mA max.
(See note 2.)
at 200-V input
1 mA max.
1.5 mA max.
2.0 mA max.
Inrush current
at 100-V input
25 A max.
(See note 2.)
at 200-V input
50 A max.
Power factor
0.5 to 0.7
(depending on the model)
0.95
Output
Voltage adjustment range
±10% (adjustable with variable resistor (V.ADJ))
Ripple
2% (p-p) max.
Input variation influence
0.4 % max. (at 85- to 132-VAC/170- to 264-VAC input, 100% load)
Load variation influence
0.8% max. (with rated input voltage, 0 to 100% load)
Temperature variation influence
0.05%/
°C max. (with rated I/O
at an ambient temperature
range between 0
°C to 50°C)
0.05%/
°C max. (with rated I/O at an ambient temperature range
between 0
°C to 40°C)
Rise time
0.8 s max. (Rises up to 90% of
the rated voltage under rated
input.)
1 s max. (Rises up to 90% of the rated voltage under rated input.)
Hold time
20 ms min.
Additional
function
Overload protection
105% max. of rated load current, inverted L drop type, automatic
reset
105% max. of rated load
current, inverted L drop type,
automatic reset (output shut off
after 5 s, reset by input reset)
Overvoltage protection
120% of rated output voltage (typical), shutoff type, input reset
Parallel operation
No
Yes, up to five
Units
No
Yes, up to five
Units
Yes, up to two Units
Series operation
Yes
Remote sensing
Yes
Remote control
No
Yes
No
Yes
Remote voltage adjustment
Yes
Cooling method
Natural air-cooling used
Forced air-cooling with built-in
fan
Fan alarm function
No
Yes