SCRs
Data Sheets
http://www.teccor.com
+1 972-580-7777
E6 - 6
2002 Teccor Electronics
Thyristor Product Catalog
* Mounted on 1cm
2
copper foil surface; two-ounce copper foil
Electrical Isolation
Teccor’s isolated SCR packages will withstand a minimum high
potential test of 2500 V ac rms from leads to mounting tab over
the device's operating temperature range. The following table
shows standard and optional isolation ratings.
* UL Recognized File #E71639
** For 4000 V isolation, use “V” suffix in part number.
Thermal Resistance (Steady State)
R
JC
[R
JA
] °C/W (TYP.)
J
Pkg.
Code
L
F
F2
R
W
K
M
D
V
N
Type
TO-220
Isolated
TO-202
Type 1
Non-isolated
TO-202
Type 2
Non-isolated
TO-220
Non-isolated
TO-218X
Isolated
TO-218X
Non-isolated
TO-218
Isolated
TO-218
Non-isolated
TO-252
D-Pak
Surface Mount
TO-251AA
V-Pak
Non-isolated
TO-263
D
Pak
Non-isolated
1 A
6 A
8 A
10 A
12 A
15 A
16 A
20 A
25 A
35 A
40 A
55 A
65 A
70 A
See below
4.0 [50]
3.4
3.0
4.3 [45]
3.9
3.4
9.5 [70]
1.7
1.5
1.45
1.4
2.3 [70]
2.0
1.7
1.6
1.8 [40]
1.6
1.5
2.5
1.3
1.3
2.4
2.35
1.0
1.0
0.70
0.70
0.6
0.5
0.6
0.5
0.53
0.53
0.86
0.86
0.60
Thermal Resistance (Steady State)
R
JC
[R
JA
] °C/W (TYP.)
C
Package Code
Type
E
Compak
35 *
TO-92
50 [145]
1 A
Electrical Isolation
*
from Leads to Mounting Tab
TO-220
Isolated
Standard
Optional **
V AC RMS
2500
4000
TO-218X
Isolated
Standard
N/A
TO-218
Isolated
Standard
N/A