www.cor.com - Libertyville, IL (847) 680-7400
P
107
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current
Frequency-MHz
Rating
.03
.1
.15
.5
1
3
5
10
30
S Models
3A
7
17
21
27
33
40
44
50
32
6A
8
12
17
23
32
36
44
30
10A
3
5
10
13
23
27
35
27
H Models
3A
7
17
21
27
30
29
26
23
15
6A
8
11
15
17
19
18
16
13
10A
3
5
8
10
12
11
10
Line-to-ground in 50 ohm circuit
Current
Frequency-MHz
Rating
.01
.05
.1
.15
0.5
1
5
10
30
Z Models
6A
8
21
27
30
37
43
49
52
42
10A
5
17
22
24
27
32
52
47
40
L Models
6A
8
21
27
29
34
35
25
21
16
10A
5
17
22
23
24
25
21
18
14
Line-to-line in 50 ohm circuit
Current
Frequency-MHz
Rating
.10
.15
.5
1
3
5
10
30
S Models
3A
2
4
12
15
30
48
50
45
6A
2
12
15
22
42
55
45
10A
2
4
12
15
22
42
55
45
H Models
3A
2
4
12
18
31
40
48
41
6A
2
4
12
16
26
35
40
35
10A
2
4
12
16
26
33
40
32
Line-to-line in 50 ohm circuit
Current
Frequency-MHz
Rating
.01
.05
.1
.15
0.5
1
5
10
30
Z Models
6A
10
15
34
44
75
70
60
10A
10
20
35
67
75
70
60
L Models
6A
10
15
34
44
75
70
60
10A
10
20
35
67
75
70
60
Series
P
Unfiltered versions of the P series includes a standard
version 0 Models that does not have an RFI filter, but
does have all other options of the P Series. It also
includes an interconnection block version B Models which
provides wiring of the IEC socket to the switch and the
switch to the fuseholder. Labor can be eliminated by
ordering the product with an interconnection block. This
feature, designated by a ‘BX0’ at the end of the part
number, prewires the module for easier installation. The
wiring is protected with the plastic case to prevent
access to the terminals and connections. Wiring can be
further simplified by ordering a PA100 connector
assembly, as shown in the accessories section. The
dimensions of this alternative are the same as the filtered
versions.
Filter Current
The P Series is available without a filter (10A rating) or in
3, 6 and 10 ampere filtered versions.
Shield Options
A feature available on the P series is an RF shield. The
metal shield, available on filtered models, provides
shielding from radiated emissions and provides an
additional RF ground for the filter to the case.
The shield is available in two versions, a shield of the filter
components (designated by A as the ninth digit) and a
complete shield (designated by B as the ninth digit).
The A shield covers the filter portion of the module and
increases performance of the filter by protecting the
components from magnetic coupling. This shield
improves RF ground connection to the case while still
Specifications – Filtered Models
H Model
Z Model
L Model
A Shield
B Shield
allowing the use of the P Series extender. The B shield
covers the entire power entry module with metal, protecting
the equipment from all radiated noise. The C shield is a
complete can for the high performance versions Used with
the filter, the shield provides the most secure protection from
RFI noise problems. The C shield cannot be used with any
extender.