SMART 5 BOOT BLOCK MEMORY FAMILY
E
26
ADVANCE INFORMATION
5.0
ELECTRICAL SPECIFICATIONS
5.1
Absolute Maximum Ratings*
Commercial Operating Temperature
During Read/Erase/Program......
0 °C to +70 °C
Temperature Under Bias ....... –10 °C to +80 °C
Extended Operating Temperature
During Read/Erase/Program.. –40 °C to +85 °C
Temperature Under Bias ....... –40 °C to +85 °C
Storage Temperature................. –65 °C to +125 °C
Voltage on Any Pin
(except V
CC
, V
PP
, A
9
and RP#)
with Respect to GND........... –2.0 V to +7.0 V
(2)
Voltage on Pin RP# or Pin A
9
with Respect to GND.......–2.0 V to +13.5 V
(2,3)
V
PP
Program Voltage with Respect
to GND during Block Erase
and Word/Byte Program..–2.0 V to +14.0 V
(2,3)
V
CC
Supply Voltage
with Respect to GND........... –2.0 V to +7.0 V
(2)
Output Short Circuit Current....................100 mA
(4)
NOTICE: This document contains information on products in
the sampling and initial production phases of development.
The specifications are subject to change without notice.
Verify with your local Intel Sales office that you have the
latest datasheet before finalizing a design.
* WARNING: Stressing the device beyond the "Absolute
Maximum Ratings" may cause permanent damage.
These
are stress ratings only.
Operation beyond the "Operating
Conditions" is not recommended and extended exposure
beyond the "Operating Conditions" may effect device
reliability.
1.
Operating temperature is for commercial product
defined by this specification.
2.
Minimum DC voltage is
–0.5 V on input/output pins.
During transitions, this level may undershoot to –2.0 V
for periods
<20 ns. Maximum DC voltage on input/output pins is
V
CC
+ 0.5 V which, during transitions, may overshoot to
V
CC
+ 2.0 V for periods <20 ns.
3.
Maximum DC voltage on V
may overshoot to +14.0 V
for periods <20 ns.
Maximum DC voltage on RP# or A
9
may overshoot to 13.5 V for periods <20 ns.
4.
Output shorted for no more than one second.
No more
than one output shorted at a time.
5.2
Operating Conditions
Symbol
Parameter
Notes
Min
Max
Units
T
A
Commercial Operating Temperature
0
+70
°C
Extended Operating Temperature
-40
+85
°C
V
CC
5 V V
CC
Supply Voltage (10%)
1
4.50
5.50
Volts
5 V V
CC
Supply Voltage (5%)
2
4.75
5.25
Volts
V
PP
5 V V
PP
Supply Voltage (10%)
1
4.50
5.50
Volts
12 V V
CC
Supply Voltage (5%)
1
11.4
12.6
Volts
NOTES:
1. 10% V
CC
specifications apply to the standard test configuration (Figures 12 and 13).
2. 5% V
CC
specifications apply to the high-speed test configuration (Figures 11 and 13).