P800 Operating Manual
33
A3 Error Messages
The following is a list of error messages that the programmer can display in local operation,
together with a list of common causes.
"BIT TEST FAIL"
One or more of the inserted devices had a bit programmed, which is required to be
unprogrammed (see section
2.4.1
).
In a flash or block erase part, BIT TEST FAIL can be returned if the limits are set to none
block boundaries, so that erasing the block would erase more that the current limits.
"CODE INCORRECT"
The security code for RAM lock was entered incorrectly.
"CONNECT ERROR"
No devices inserted,
Device(s) incorrectly seated in their sockets
Device(s) fitted in the wrong part of the ZIF socket (see section
2.2
)
Device(s) fitted the wrong way round.
Lever on a ZIF socket in incorrect position
Device(s) in the wrong position for load (see section
2.2.1
)
Device(s) faulty.
See also the device support list for part specific instructions on inserting parts.
"EMPTY FAIL"
One or more of the inserted parts was found to be not empty, or would not erase.
"FUNCTION DISABLED"
Ram lock has been selected see section
2.9.3
.
"INVALID STATUS CODE"
Software is corrupted - contact your authorised distributor.
"LOAD ERROR"
An error was detected on the data inputted from the port, or the input was aborted.
"MISMATCHED PARTS"
When Electronic ID is set to auto, and parts of incompatible programming algorithms are
inserted, and a programming function is selected.
On some parts, 2 dies are marked externally the same but program differently. On these
parts it is necessary for the programmer to read an electronic signature, to determine how
to program the part. If parts of different dies are detected, then the programmer will return
MIS MATCHED PARTS. The parts must be programmed in two lots.
"No or incorrect Module"
There is no module fitted, that is correct for the currently selected part, or the module is
incorrectly fitted.