LT1004-1.2, LT1004-2.5
MICROPOWER INTEGRATED VOLTAGE REFERENCES
SLVS022M JANUARY 1989 REVISED MAY 2008
4
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Reverse current, IR
30 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Forward current, IF
10 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package thermal impedance,
θJA (see Notes 1 and 2): D package
97
°C/W
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
PW package
149
°C/W
. . . . . . . . . . . . . . . . . . . . . . . . .
Operating virtual junction temperature, TJ
150
°C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
260
°C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, Tstg
65
°C to 150°C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. Maximum power dissipation is a function of TJ(max),
θJA, and TA. The maximum allowable power dissipation at any allowable
ambient temperature is PD = (TJ(max) TA)/
θJA. Operating at the absolute maximum TJ of 150°C can affect reliability.
2. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions
MIN
MAX
UNIT
T
Operating free air temperature
LT1004C
0
70
°C
TA
Operating free-air temperature
LT1004I
40
85
°C
electrical characteristics at specified free-air temperature
PARAMETER
TEST
T
LT1004-1.2
LT1004-2.5
UNIT
PARAMETER
TEST
CONDITIONS
TA
MIN
TYP
MAX
MIN
TYP
MAX
UNIT
25
°C
1.231
1.235
1.239
2.48
2.5
2.52
VZ
Reference voltage
IZ = 100 A
Full
LT1004C
1.225
1.245
2.47
2.53
V
VZ
Reference voltage
IZ
100
A
Full
range
LT1004I
1.225
1.245
2.47
2.53
V
a
V
Average
temperature coefficient
IZ = 10 A
25
°C
20
ppm/
°C
a
V
Z
temperature coefficient
of reference voltage§
IZ = 20 A
25
°C
20
ppm/
°C
I
I (min) to 1 mA
25
°C
1
V
Change in
reference voltage
IZ = IZ(min) to 1 mA
Full range
1.5
mV
VZ
reference voltage
with current
I
1mAto20mA
25
°C
10
mV
with current
IZ = 1 mA to 20 mA
Full range
20
VZ/t
Long-term change
in reference voltage
IZ = 100 A
25
°C
20
ppm/khr
IZ(min)
Minimum
reference current
Full range
8
10
12
20
A
z
Reference impedance
I
100 A
25
°C
0.2
0.6
0.2
0.6
zz
Reference impedance
IZ = 100 A
Full range
1.5
Vn
Broadband
noise voltage
IZ = 100 A,
f = 10 Hz to 10 kHz
25
°C
60
120
V
Full range is 0
°C to 70°C for the LT1004C and 40°C to 85°C for the LT1004I.
§ The average temperature coefficient of reference voltage is defined as the total change in reference voltage divided by the specified temperature
range.