      Cassette Style
      100 Watt AC-DC Converters
      S Series PFC
      Edition 01/01.2001
      19/27
      Safety and Installation Instructions
      Connector Pin Allocation
      The connector pin allocation table defines the electrical
      potentials and the physical pin positions on the H15 con-
      nector. Pin no. 24, the protective earth pin present on all LS
      AC-DC converters is leading, ensuring that it makes con-
      tact with the female connector first.
      4
      32
      Type H15
      10002
      Table 12: H15 Connector pin allocation
      Pin
      Connector type H 15
      No.
      LS 4000
      LS 5000
      4
      Vo1+
      Output 1
      Vo2+
      Output 2
      6
      Vo1+
      Vo2+
      8Vo1–
      Output 1
      Vo2–
      Output 2
      10
      Vo1–
      Vo2–
      12
      S+
      Sense
      Vo1+
      Output 1
      14
      S–
      Sense
      Vo1–
      Output 1
      16
      R 1
      Control of
      U o1
      R 1
      Control of
      U o1
      18
      i
      Inhibit
      i
      Inhibit
      20
      D
      Save data
      D
      Save data
      V 3
      ACFAIL
      22
      T
      Current sharing
      T
      Current sharing
      24 2
      Protective earth
      26
      N
      Neutral
      N
      Neutral
      28
      N
      N
      30
      P
      Phase
      P
      Phase
      32
      P
      P
      1 Feature R excludes option P and vice versa
      2 Leading pin (pregrounding)
      3 Option D excludes option V and vice versa
      Installation Instructions
      The S series AC-DC converters are components, intended
      exclusively for inclusion within other equipment by an in-
      dustrial assembly operation or by professional installers. In-
      stallation must strictly follow the national safety regulations
      in compliance with the enclosure, mounting, creepage,
      clearance, casualty, markings and segregation require-
      ments of the end-use application.
      Connection to the system shall be made via the female con-
      nector H15 (see:
      Accessories). Other installation methods
      may not meet the safety requirements.
      The AC-DC converters are provided with pin no. 24 ( ),
      which is reliably connected with their case. For safety rea-
      sons it is essential to connect this pin with the protective
      earth of the supply system.
      An input fuse is built-in in the connection from pins no. 30
      and 32 (P
      ) of the unit. Since this fuse is designed to pro-
      tect the unit in case of an overcurrent and does not neces-
      sarily cover all customer needs, an external fuse suitable
      for the application and in compliance with the local require-
      ments might be necessary in the wiring to one or both input
      potentials, pins nos. 26 and 28 and/or nos. 30 and 32.
      Important: Whenever the inhibit function is not in use,
      pin no. 18 (i) should be connected to pin no. 14 (S–/Vo1–)
      to enable the output(s).
      Do not open the modules, or guarantee will be invali-
      dated.
      Due to high current values, all LS units provide two inter-
      nally parallel connected contacts for certain paths (pins 4/6,
      8/10, 26/28 and 30/32, respectively). It is recommended to
      connect load and supply to both female connector pins of
      each path in order to keep the voltage drop across the con-
      nector pins to an absolute minimum and to not overstress
      the connector contacts if currents are higher than
      approx. 8 A. The connector contacts are rated 8 A over the
      whole temperature range.
      Make sure that there is sufficient air flow available for con-
      vection cooling. This should be verified by measuring the
      case temperature when the unit is installed and operated in
      the end-use application. The maximum specified case tem-
      perature
      TC max shall not be exceeded. See also: Thermal
      Considerations.
      Check for hazardous voltages before altering any connec-
      tions.
      Ensure that a unit failure (e.g. by an internal short-circuit)
      does not result in a hazardous condition. See also:
      Safety
      of operator accessible output circuit.
      Cleaning Agents
      In order to avoid possible damage, any penetration of
      cleaning fluids is to be prevented, since the power supplies
      are not hermetically sealed.
      Fig. 27
      View of module’s male H15 connector
      Protection Degree
      Condition: Female connector fitted to the unit.
      IP 30: All units except those with option P, and except
      those with option D or V with potentiometer.
      IP 20: All units fitted with option P, or with option D or V with
      potentiometer.
      相關(guān)PDF資料
      PDF描述
      LS5540-7PD2TB1 2-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
      LS5540-7PD7TB1 2-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
      LS5540-7PD7T 2-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
      LS5540-9RD2T 2-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
      LS5660-7ERD0TB1 2-OUTPUT 100 W AC-DC PWR FACTOR CORR MODULE
      相關(guān)代理商/技術(shù)參數(shù)
      參數(shù)描述
      LS5540-7R 功能描述:線性和開關(guān)式電源 Euro-Cassette 100W (2x 15V) RoHS:否 制造商:TDK-Lambda 產(chǎn)品:Switching Supplies 開放式框架/封閉式:Enclosed 輸出功率額定值:800 W 輸入電壓:85 VAC to 265 VAC 輸出端數(shù)量:1 輸出電壓(通道 1):20 V 輸出電流(通道 1):40 A 商用/醫(yī)用: 輸出電壓(通道 2): 輸出電流(通道 2): 安裝風(fēng)格:Rack 長度: 寬度: 高度:
      LS5540-9ER 制造商:Power-One 功能描述:ACDC - Bulk
      LS5-544 功能描述:打印機 LS5, Laminated Continuous Tape, Polyeste RoHS:否 制造商:Seiko Instruments 產(chǎn)品:Printer 電源電壓: 每行點數(shù):9 x 320 打印速度:52.5 cps, 80 cps 紙張寬度:112 mm
      LS5-547 制造商:Panduit Corp 功能描述:
      LS5-60 制造商:Panduit Corp 功能描述: