2
ISO164/ISO174
SPECIFICATIONS
At T
A
= +25
°
C, V
S1
= V
S2
=
±
15V, and R
L
= 2k
, unless otherwise noted.
ISO164P
ISO174P
PARAMETER
CONDITIONS
MIN
TYP
MAX
MIN
TYP
MAX
UNITS
ISOLATION
(1)
Voltage Rated Continuous:
AC
100% Test (AC 50Hz)
Isolation-Mode Rejection
AC 50Hz
Barrier Impedance
Leakage Current
T
MIN
to T
MAX
1500
2500
1500
2500
Vrms
Vrms
1s; Partial Discharge
≤
5pC
1500Vrms
115
115
dB
10
14
|| 10
0.8
10
14
|| 10
0.8
|| pF
μ
Arms
VISO = 240Vrms, 50Hz
1
1
GAIN
Gain Error
G = 1
G = 10
G = 100
G = 1
G = 10
G = 100
G = 1
G = 10
G = 100
±
0.3
±
0.3
%
±
0.06
±
0.06
±
0.3
±
0.3
%
Gain vs Temperature
±
12.5
±
12.5
±
12.5
±
0.01
±
0.01
±
0.01
±
42.5
±
42.5
±
42.5
±
0.04
±
0.04
±
0.04
ppm/
°
C
ppm/
°
C
ppm/
°
C
%
%
%
Nonlinearity
±
0.052
±
0.102
±
0.054
±
0.104
INPUT OFFSET VOLTAGE
Initial Offset
mV
vs Temperature
vs Supply
CMRR
G = 1
DC, G = 1
DC, G = 1
±
155
2
90
±
505
2
90
μ
V/
°
C
mV/V
dB
INPUT
Voltage Range
Bias Current
vs Temperature
Offset Current
vs Temperature
±
10.0
±
10.0
V
nA
±
5
±
5
±
8
±
8
pA/
°
C
nA
pA/
°
C
±
5
±
5
±
8
±
8
OUTPUT
Voltage Range
Current Drive
Capacitive Load Drive
Ripple Voltage
±
10
±
5
±
10
±
5
V
mA
μ
F
mVp-p
0.1
10
0.1
10
FREQUENCY RESPONSE
Small Signal Bandwidth
100mVrms, G = 1
100mVrms, G = 10
100mVrms, G = 100
V
O
=
±
10V, G = 10
6
6
6
60
60
10
0.7
kHz
kHz
kHz
V/
μ
s
Slew Rate
0.7
POWER SUPPLIES
Rated Voltage
Voltage Range
Quiescent Current
V
S1
V
S2
15
15
V
V
±
4.5
±
18
±
4.5
±
18
±
15
±
7.5
±
15
±
7.5
mA
mA
TEMPERATURE RANGE
Operating
Storage
–40
–40
85
125
–40
–40
85
125
°
C
°
C
NOTE: (1) All devices receive a 1s test. Failure criterion is
≥
5 pulses of
≥
5pc.
±
0.125
+
51
G
±
0.125
+
101
G
The information provided herein is believed to be reliable; however, BURR-BROWN assumes no responsibility for inaccuracies or omissions. BURR-BROWN assumes
no responsibility for the use of this information, and all use of such information shall be entirely at the user's own risk. Prices and specifications are subject to change
without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. BURR-BROWN does not authorize or warrant
any BURR-BROWN product for use in life support devices and/or systems.