www.irf.com
5
IRS213(6,62,63,65,66,67,68)D(J&S)PbF
Static Electrical Characteristics - (Continued)
V
BIAS
(V
CC
,V
BS1,2,3
) = 15 V unless otherwise specified. The V
IN
, V
TH
, and I
IN
parameters are referenced to V
SS
and are
applicable to all six channels (HIN1,2,3/HIN1,2,3 and LIN1,2,3). The V
O
and I
O
parameters are referenced to COM and
V
S1,2,3
and are applicable to the respective output leads: LO1,2,3 and HO1,2,3.
Symbol
Definition
Min. Typ. Max. Units
Test
Conditions
V
RCIN
= 0 V or
15 V
Vo =0 V,
PW
≤
10 μs
Vo =15 V,
PW
≤
10 μs
I
RCIN
RCIN input bias current
—
—
1
μA
I
O+
Output high short circuit pulsed current
120
200
—
I
O-
Output low short circuit pulsed current
250
350
—
mA
R
on_RCIN
R
on_FAULT
R
BS
RCIN low on resistance
FAULT low on resistance
—
—
—
50
50
200
100
100
—
I= 1.5 mA
Internal BS diode R
ON
Note 1:
Please refer to Feature Description section for integrated bootstrap functionality information.
Dynamic Electrical Characteristics
Dynamic Electrical Characteristics V
CC
= V
BS
= V
BIAS
= 15 V, V
S1,2,3
= V
SS
= COM, T
A
= 25 °C and CL = 1000 pF unless
otherwise specified.
Symbol
Definition
Min. Typ. Max. Units
Test
Conditions
t
on
t
off
Turn-on propagation delay
Turn-off propagation delay
Turn-on propagation delay
Turn-off propagation delay
Turn-on rise time
Turn-off fall time
ENABLE low to output shutdown propagation
delay
ENABLE low to output shutdown propagation
delay
ITRIP to output shutdown propagation delay
ITRIP blanking time
ITRIP to FAULT propagation delay
Input filter time (HIN, LIN)
(IRS213(6,62,63,65,68)D only)
Enable input filter time
(IRS213(6,62,63,65,68)D only)
400
400
—
—
—
—
530
530
200
200
125
50
750
750
—
—
190
75
t
on
(66,67)
t
off
(66,67)
t
r
t
f
V
IN
= 0 V & 5 V
t
EN
350
460
650
t
EN
(66,67)
—
300
—
V
IN,
V
EN
= 0 V
or 5 V
t
ITRIP
t
bl
t
FLT
500
—
400
750 1200
400
600
V
ITRIP
=5 V
—
950
V
IN
= 0 V or 5 V
V
ITRIP
= 5 V
t
FILIN
200
350
510
V
IN
= 0 V & 5 V
t
filterEN
100
200
—
DT
Deadtime
190
290
420
V
IN
= 0 V & 5 V
external dead
time
External dead
time >420 ns
External dead
time 0 s
PW input=10 μs
V
IN
= 0 V or 5 V
V
ITRIP
= 0 V
MT
t
on
, t
off
matching time (on all six channels)
—
—
50
MDT
DT matching (Hi->Lo & Lo->Hi on all channels)
—
—
60
PM
Pulse width distortion (pwin-pwout)
FAULT clear time RCIN: R = 2 M
, C = 1 nF
—
—
75
ns
t
FLTCLR
1.3
1.65
2
ms
Note 2:
For high side PWM, HIN pulse width must be
≥
500 ns.
PRELIMINARY