IR6311G
Absolute Maximum Ratings
Absolute Maximum Ratings indicate sustained limits beyond which
damage to the device may occur. (T
c
= 25
o
C unless otherwise specified.)
2
Symbol Parameter
V
ccop
Operating Voltage Range
I
ccoff
Sleep Mode Supply Current
I
ccon
Supply Current (Average)
I
ccac
Supply Current (AC RMS)
V
ih
High Level Input Threshold Voltage
V
il
Low Level Input Threshold Voltage
I
lon
On-State Input Current
I
loff
Off-State Input Current
I
oh
Output Leakage Current
I
ol
Output Leakage Current
V
dgl
Low Level Diagnostic Output Voltage
I
dgh
Diagnostic Output Leakage Current
R
DS(on)
On-State Resistance
Min.
5
—
—
—
—
1
10
1
—
0
—
0
—
Typ.
—
30
1
20
2
1.8
—
—
20
—
0.3
—
120
Max. Units Test Conditions
50
V
—
μ
A
V
cc
=24V, V
in
=0V
—
mA
V
in
= 5V
—
μ
A
V
in
= 5V
2.5
V
—
140
V
in
= 5.5V
30
μ
A
—
V
out
= 6V
10
V
out
= 0V
—
V
I
dg
= 1.6mA
10
μ
A
V
dg
= 5V
150
m
V
in
= 0.4V
I
out
= 1A
Symbol Parameter
Vcc
Supply Voltage
Min.
-0.3
-16
Vcc -50
-0.3
—
Vcc -50
—
-0.3
—
—
—
—
—
-40
-40
Max.
50
—
Vcc +0.3
7
10
Vcc +0.3
self-limited
7
10
100
4000
500
2
150
150
Units
Test Conditions
Pin 5 to Pin 3
(1), for 10 seconds
Permanent
Reverse
V
Voffset
Vin
Iin
Vout
Iout
Vdg
Idg
Eav
ESD1
ESD2
PD
T
Jop
T
Stg
Logic to Power Ground Offset
Input Voltage
Input Current
Output Voltage
Output Current
Diagnostic Output Voltage
Diagnostic Output Current
Repetitive Avalanche Energy
Electrostatic Discharge
(Human Body Model)
Electrostatic Discharge
(Machine Model)
Power Dissipation
Operating Junction Temperature Range
Storage Temperature Range
mA
V
A
V
mA
mJ
V
V
W
I = 2A(2)
C=100 pF, R = 1500
C=200 pF, R = 0
Tambient=25
C
o
C
NOTES:
(1) with 15k
resistors in input and diagnostic (2) maximum frequency depends on heatsink (rectangular
waveform)
Static Electrical Characteristics
(T
c
= 25
o
C and V
cc
= 16V unless otherwise specified.)
Switching Electrical Characteristics
(V
CC
= 14V, Resistive Load (R
L
) = 12
, T
C
= 25
o
C.)
Symbol Parameter
tc
Over-Current Cycle Time
Dc
Over-Current Duty Cycle
t
on
Turn-On Delay Time to 90%
t
off
Turn-Off Delay Time to 10%
dv/dt
on
Slew Rate On
dv/dt
off
Slew Rate Off
Min.
—
—
—
—
—
—
Typ.l Max. Units Test Conditions
3
—
mS
10
—
%
50
—
60
—
3
—
5
—
V/
μ
s
μ
s