Absolute Maximum Ratings
Electrical Characteristics(Ta=25C)
Dimensional Drawing (mm)
Classification of Output Hall Voltage (V
H
)
I
I
25
Note : When ordering, specify 3-rank or wider range(e·g·,BCD).
Input Current Derating Curve
Input Voltage Derating Curve
Note : For constant-voltage drive, stay within this input voltage derating
curve envelope.
Note : R
in
of Hall element decreases rapidly as ambient temperature
increases. Ensure compliance with input current derating curve envelope,
throughout the operating temperature range.
20
10
–40
–20
0
20
40
60
80
100
120
Input Resistance
Rin : 240 to 550
2.0
1.0
–40
–20
0
20
40
60
80
100
120
0.4
1.0 1.0
1.0
0.4
0.3
0
0
1
8
2
0
2.7±0.1
10
10
0.2
1.05
0
N
1.65±0.1
5
0
Ambient Temperature.(C)
Item
Symbol
Topr.
Tstg.
Ic
Const. Current Drive
Limit
20
–40 to +125
–40 to +110
Unit
mA
C
C
Pinning
Conditions
V
H
[ mV ]
Rank
B=50mT, Vc=IV
Constant Voltage Drive
Max. Input Current
Operating Temp. Range
Storage Temp. Range
Dielectric Strength
Output Hall Voltage
Input Resistance
Output Resistance
Offset Voltage
Temp. Coefficient of V
H
Temp. Coefficient of Rin
Item
100V D.C
Const. Voltage Drive
B=50mT, Vc=IV
B=0mT, Ic=0.1mA
B=0mT, Ic=0.1mA
B=0mT, Vc=IV
B=50mT, Ic=5mA
B=0mT, Ic=0.1mA
Conditions
1.0
122
240
240
–7
Min.
mV
mV
%/C
%/C
Unit
–1.8
–1.8
Typ.
550
320
550
+7
Max.
1(±)
3
(
Input
2(±)
4
(
Output
A
122 to 150
B
144 to 174
C
168 to 204
D
196 to 236
F
266 to 320
E
228 to 274
Input Resistance
Rin : 240 to 550
4
3
2
1
M
V
H
Rin
Rout
Vos
V
H
Rin
Symbol
Notes : 1. V
H
= VHM – V
os
(VHM:meter indication)
2. V
H
= X X 100
3. R
in
= X X 100
T
1
= 20C, T
2
= 0C, T
3
= 40C
in
3
in
2
H
3
H
2
0
Ambient Temperature.(C)
Note : It is requested to read and accept "IMPORTANT NOTICE".
Please be aware that AKE products are not intended for use in life
support equipment, devices, or systems. Use of AKE products in such
applications requires the advance written approval of the appropriate
AKE officer.
Certain applications using semiconductor devices may involve potential
risks of personal injury, property damage, or loss of life. In order to
minimize these risks, adequate design and operating safeguards
should be provided by the customer to minimize inherent or procedural
hazards. Inclusion of AKE products in such applications is understood to
be fully at the risk of the customer using AKE devices or systems.