Column address hold time
t
CAH
10
10
ns
Column address hold referenced to /RAS
t
AR
40
45
ns
Column Address to /RAS lead time
t
RAL
25
30
ns
Read command set-up time
t
RCS
0
0
ns
Read command hold referenced to /CAS
t
RCH
0
0
ns
Read command hold referenced to /RAS
t
RRH
0
0
ns
Write command hold time
t
WCH
10
10
ns
Write command hold referenced to /RAS
t
WCR
40
45
ns
Write command pulse width
t
WP
10
10
ns
Write command to /RAS lead time
t
RWL
15
15
ns
Write command to /CAS lead time
t
CWL
13
15
ns
Data-in set-up time
t
DS
0
0
ns
Data-in hold time
t
DH
10
15
ns
Data-in hold referenced to /RAS
t
DHR
40
45
ns
Refresh period 2K Ref.
t
REF
32
32
ns
Write command set-up time
t
WCS
0
0
ns
/CAS setup time (C-B-R refresh)
t
CSR
5
5
ns
/CAS hold time (C-B-R refresh)
t
CHR
10
10
ns
/RAS precharge to /CAS hold time
t
RPC
5
5
ns
Access time from /CAS precharge
t
CPA
30
35
ns
Fast page mode cycle time
t
PC
35
40
ns
/CAS precharge time (Fast page)
t
CP
10
10
ns
/RAS pulse width (Fast page)
t
RASP
50
200K
60
200K
ns
/WE to /RAS precharge time (C-B-R refresh)
t
WRP
10
10
ns
/WE to /RAS hold time (C-B-R refresh)
t
WRH
10
10
ns
/CAS precharge(C-B-R counter test)
NOTES
1.
An initial pause of 200
μ
s is required after power-up followed by any 8 /RAS-only or /CAS-before-/RAS refresh cycles
before proper device operation is achieved.
2.
V
IH (min)
and V
IL (max)
are reference levels for measuring timing of input signals. Transition times are measured between
V
IH(min)
and V
IL(max)
and are assumed to be 5ns for all inputs.
3.
Measured with a load equivalent to 2TTL loads and 100pF.
4.
Operation within the t
limit insures that t
can be met. t
is specified as a reference point only.
If t
RCD
is greater than the specified t
RCD(max)
limit, then access time is controlled exclusively by t
CAC
.
5.
Assumes that t
≥
t
6. t
, t
, t
are referenced to t
7.This parameter defines the time at which the output achieves the open circuit condition and is not referenced to V
OH
or
V
OL
.
8. t
WCS
, t
RWD
, t
CWD
and t
AWD
are non restrictive operating parameter.
They are included in the data sheet as electrical characteristic only. If t
≥
tWCS(min)
the cycle is an early write cycle and
the data out pin will remain high impedance for the duration of the cycle.
9. Either t
or t
must be satisfied for a read cycle.
10. These parameters are referenced to the /CAS leading edge in early write cycles and to the /W leading edge in read-
write cycles.
11. Operation within the t
limit insures that t
can be met. t
is specified as a reference point only.
If t
RAD
is greater than the specified t
RAD(max)
limit. then access time is controlled by t
AA
.
t
CPT
20
20