8-Bit, 40/60/75/80 MSPS A/D Converter
The HI5714 is a high precision, monolithic, 8-bit, Analog-to-
Digital Converter fabricated in Intersil’ advanced HBC10
BiCMOS process.
The HI5714 is optimized for a wide range of applications such as
ultrasound imaging, mass storage, instrumentation, and video
digitizing, where accuracy and low power consumption are
essential. The HI5714 is offered in 40 MSPS, 60 MSPS, and 75
MSPS sample rates.
The HI5714 delivers
±0.4 LSB differential nonlinearity while
consuming only 325mW power (Typical) at 75 MSPS. The
digital inputs and outputs are TTL compatible, as well as
allowing for a low-level sine wave clock input.
Features
Sampling Rate . . . . . . . . . . . . . . . . . . . 40/60/75/80 MSPS
Low Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325mW
7.65 ENOB at 4.43MHz
Overflow/Underflow Three-State TTL Output
Operates with Low Level AC Clock
Very Low Analog Input Capacitance
No Buffer Amplifier Required
No Sample and Hold Required
TTL Compatible I/O
Pin-Compatible to Philips TDA8714
Pb-free Available
Applications
Video Digitizing
QAM Demodulator
Digital Cable Setup Box
Tape Drive/Mass Storage
Medical Ultrasound Imaging
Communication Systems
Pinout
HI5714 (SOIC)
TOP VIEW
Ordering Information
PART
NUMBER
TEMP.
RANGE
(°C)
PACKAGE
SAMPLING
FREQUENCY
(MHz)
PKG.
DWG. #
HI5714/4CB
0 to 70
24 Ld SOIC
40
M24.3
HI5714/4CBZ
(Note)
0 to 70
24 Ld SOIC
(Pb-free)
40
M24.3
HI5714/7CB-T
0 to 70
24 Ld SOIC
Tape & Reel
75
M24.3
HI5714/7CBZ-T
(Note)
0 to 70
24 Ld SOIC
Tape & Reel
(Pb-free)
75
M24.3
HI5714EVAL
25
Evaluation Board
NOTE: Intersil Pb-free products employ special Pb-free material
sets; molding compounds/die attach materials and 100% matte tin
plate termination finish, which is compatible with both SnPb and
Pb-free soldering operations. Intersil Pb-free products are MSL
classified at Pb-free peak reflow temperatures that meet or exceed
the Pb-free requirements of IPC/JEDEC J Std-020B.
1
2
3
4
5
6
7
8
9
10
11
12
D1
D0
NC
VRB
NC
AGND
VCCA
VIN
VRT
NC
O/UF
D7
16
17
18
19
20
21
22
23
24
15
14
13
D2
OE
VCCO2
OGND
VCCO1
DGND
D4
D5
D6
D3
VCCD
CLK
FN3973.6
HI5714
Data Sheet
July 2004