FEATURES
dual channel signal processing
2nd (4th) order state variable filter
adjustable crossover frequency
adjustable compression ratio from 1:1 to 4:1
independent compression ratio adjustment for
low and high frequency band
adjustable AGC threshold levels
unique twin average detectors
handles high input levels
low THD and IMD distortion
drives class D Integrated Receivers
MPO range externally adjustable
reflowable package
STANDARD PACKAGING
Hybrid Typical Dimensions
0.250 in x 0.115 in x 0.080 in
(6.35 mm x 2.91 mm x 2.03 mm)
DynamEQ
II
WDRC System
FUNCTIONAL BLOCK DIAGRAM
All resistors in ohms, all capacitors
in microfarads, unless otherwise stated
Patent Pending
OUT
V
B
16
V
REG
R
TH
MPO
IN
GND
Rc
R
LO
13
B
OUT
BC
IN
B
IN
F
OUT
R
HI
12
4:1
11
2:1
10
1:1
14
0
μ
22
C6
C7
0
μ
22
GR3031
(GR3032)
10n
C1
0
μ
1
C2
C5
C4
C3
0
μ
1
0
μ
1
0
μ
2
SLOW
AVERAGE
DETECTOR
FAST
AVERAGE
DETECTOR
CONTROL
10k
RECTIFIER
Vb
50k
REGULATOR
48k
48k
8k4
1M
1M
14k
12k
1
X
- B
- A
- C
12 dB / Oct
(24 dB / Oct)
BAND SPLIT
FILTER
High Frequency
Expander / Compressor
Low Frequency
Expander / Compressor
RAGC_IN
RH
RL
5
7
9
17
15
8
6
2
1
3
4
Revision Date: May 1998
GR3031/GR3032 - DATA SHEET
DEVICE DESCRIPTION
The DynamEQ
II hybrid family is a second generation Wide
Dynamic Range Compression (WDRC) system.
GR3031 (GR3032) hybrid incorporates 12 dB/oct (24 dB/oct)
filtering. All capacitors necessary for operation are included.
The hybrid was designed for reflowability.
The gain and frequency response is dependant on the user’s
environment.
Twin averaging detector circuits are optimized for sound quality
during normal listening without sacrificing comfort during
sudden loud inputs.
All input signals to DynamEQ
II, are processed by 2:1
compression before subsequent band splitting.
The 12 dB/oct (24 dB/oct) band split filter ahead of the
expander/compressor circuits allows for independent
compression ratio adjustment (1:1 to 4:1) in high and low
frequency channels.
The gain setting stage is followed by a Class D Integrated
Receiver preamplifier stage. Symmetrical peak clipping is
used to achieve MPO adjustment.
Document No. 521 - 35 - 03
GENNUM CORPORATION P.O. Box 489, Stn. A, Burlington, Ontario, Canada L7R 3Y3 tel. +1 (905) 632-2996