G6J-Y
Engineering Data
Switching voltage (V)
S
w
it
c
h
in
g
c
u
rr
e
n
t(
A)
10
7
5
3
0.1
1
3
5
10
30 50
100
300 500 1,000
0.7
1
0.5
0.3
AC resistive load
DC resistive load
Ambient temperature (°C)
40
20
0
20
40
60
80
100
250
200
150
100
50
0
M
a
x
im
u
m
v
o
lt
a
g
e
(
%
)
40
20
0
20
40
60
80
100
1.2
1
0.8
0.6
0.4
0.2
0
Ambient temperature (°C)
S
w
it
c
h
in
g
c
u
rr
e
n
t(
A)
Maximum Switching Capacity
Ambient Temperature vs.
Maximum Voltage
Ambient Temperature
vs. Switching Current
Note: “Maximum voltage” is the maximum voltage that can
be applied to the Relay coil.
1,000
500
300
100
50
30
10
5
3
1
0
0.2
0.4
0.6
0.8
1
1.2
Switching current (A)
30 VDC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
125 VAC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
S
w
it
c
h
in
g
o
p
e
ra
ti
o
n
s
(
x
1
0
4 o
p
e
ra
ti
o
n
s)
max.
avg.
min.
avg.
min.
max.
Maximum estimated value
100
90
80
70
60
50
40
30
20
10
0
60
40
20
0
20
40
60
80 100
Ambient temperature (°C)
Operating voltage
Release voltage
C
h
a
n
g
e
r
a
te
o
n
t
h
e
b
a
s
is
o
fr
a
te
d
v
o
lt
a
g
e
(
%
)
Z
Z'
Y
Y'
X
X'
200
400
600
800
1,000
800
600
400
200
1,000
Shock directions
Unit: m/s2
Sample: G6J-2P-Y
Number of Relays: 10
X
X'
Not
energized
Energized
Z
Z'
Y
Y'
Electrical Endurance
Ambient Temperature vs. Must
Operate or Must Release Voltage
Shock Malfunction
Conditions: Shock is applied in ±X, ±Y, and ±Z directions
three times each with and without energizing the Relays
to check the number of contact malfunctions.
0.001 0.01
0.1
1
10
100
1,000
Operating frequency (x103 operations)
100
80
60
40
20
0
max.
min.
max.
min.
Release voltage
Operate voltage
O
n
t
h
e
b
a
s
is
o
fr
a
te
d
v
o
lt
a
g
e
(
%
)
Sample: G6J-2P-Y
Number of Relays: 10
Test conditions: 1-A resistive load at
30 VDC with an operation rate of 50%
Switching frequency: 1,800 operations/hour
Operating frequency (x103 operations)
C
o
n
ta
c
tr
e
s
is
ta
n
c
e
(
m
)
0.001 0.01
0.1
1
10
100
1,000
NO contact
NC contact
1,000
500
300
100
50
30
10
max.
min.
max.
Contact resistance
Sample: G6J-2P-Y
Number of Relays: 10
Test conditions: 1-A resistive load
at 30 VDC with an operation rate
of 50% Switching frequency:
1,800 operations/hour
Operating frequency (x105 operations)
Contact
resistance
(m
)
0.001 0.01
0.1
1
10
100
1,000
500
300
100
50
30
10
max.
min.
max.
Sample: G6J-2P-Y
Number of Relays: 10
Test conditions: 10 A resistive load
at 10 m VDC with an operation rate
of 50% Switching frequency: 7,200
operations/hour
Contact resistance
NO contact
NC contact
Electrical Endurance (with
Operate and Release Voltage)
(See note 1.)
Electrical Endurance (Contact
resistance) (See note 1.)
Contact Reliability Test
(See notes 1 and 2.)
Note:
1.
The tests were conducted at an ambient temperature of 23°C.
2.
The contact resistance data are periodically measured reference values and are not values from each monitoring operation. Contact resistance values will vary according
to the switching frequency and operating environment, so be sure to check operation under the actual operating conditions before use.