2
G5V-2
G5V-2
High Sensitivity Models
Note:
1.
The rated current and coil resistance are measured at a coil temperature of 23
°
C with a tolerance of
±
10%.
2.
Operating characteristics are measured at a coil temperature of 23
°
C.
I
Contact Ratings
Note
I
Characteristics
Note:
P level:
60
= 0.1 x 10
–
6
/operation
Rated voltage
Rated current
Coil resistance
Coil inductance
(H) (ref. value)
3 VDC
50 mA
60
W
0.18
0.57
75% max. of rated voltage
5% min. of rated voltage
180% of rated voltage at 23
°
C
5 VDC
30 mA
166.7
W
0.46
0.71
6 VDC
25 mA
240
W
0.70
0.97
9 VDC
16.7 mA
540
W
1.67
2.33
12 VDC
12.5 mA
960
W
2.90
3.99
24 VDC
8.33 mA
2,880
W
6.72
9.27
48 VDC
6.25 mA
7,680
W
20.1
26.7
Armature ON
Armature OFF
Must operate voltage
Must release voltage
Max. voltage
150% of rated
voltage at
23
°
C
Approx.
300 mW
Power consumption
Approx. 150 mW
Approx.
200 mW
Item
Standard models
High sensitivity models
Load
Rated load
Contact material
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Failure rate (reference value)
Resistive load (cos
f
= 1)
0.5 A at 125 VAC; 2 A at 30 VDC
Ag + Au-clad
2 A
125 VAC, 125 VDC
2 A
62.5 VA, 60 W
0.01 mA at 10 mVDC
0.5 A at 125 VAC; 1 A at 24 VDC
1 A
62.5 VA, 24 W
Item
Standard models
High sensitivity models
100 m
W
max.
Contact resistance
Operate time
Release time
Bounce time
50 m
W
max.
7 ms max.
3 ms max.
Operate: approx. 0.3 ms
Release: approx. 1.5 ms
Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
1,000 M
W
min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 min between coil
and contacts
1,000 VAC, 50/60 Hz for 1 min between con-
tacts of different polarity
750 VAC, 50/60 Hz for 1 min between contacts
of same polarity
1,500 V (10 x 160
μ
s) between coil and contacts (conforms to FCC Part 68)
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s
2
(approx. 100G)
Malfunction: 200 m/s
2
(approx. 20G)
Mechanical: 15,000,000 operations min. (at 36,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr)
Operating:
-
25
°
C to 65
°
C (with no icing)
Operating: 5% to 85%
Approx. 5 g
Max. operating frequency
Insulation resistance
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between coil
and contacts
1,000 VAC, 50/60 Hz for 1 min between con-
tacts of different polarity
500 VAC, 50/60 Hz for 1 min between contacts
of same polarity
Impulse withstand voltage
Vibration resistance
Shock resistance
Destruction: 1,000 m/s
2
(approx. 100G)
Malfunction: 100 m/s
2
(approx. 10G)
Endurance
Ambient temperature
Ambient humidity
Weight
Operating:
-
25
°
C to 70
°
C (with no icing)