G5S
G5S
Specifications
COIL RATINGS
Rated voltage
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
Power consumption
5 VDC
80 mA
62.5
75% max. of rated voltage
5% min. of rated voltage
150% of rated voltage at 23
°
C, 110% of rated voltage at 70
°
C
Approx. 400 mW
9 VDC
44.4 mA
202.5
12 VDC
33.3 mA
360
18 VDC
22.2 mA
810
24 VDC
16.7 mA
1,440
48 VDC
8.3 mA
5,760
Note: Rated current and coil resistance are measured at 23
°
C with a tolerance of
±
10%.
CONTACT RATINGS
Load
Rated load
Resistive load
2 A (NO)/2 A (NC) at 277 VAC
5 A (NO)/3 A (NC) at 125 VAC
5 A (NO)/3 A (NC) at 30 VDC
Ag
5 A (NO)/3 A (NC)
277 VAC, 30 VDC
5 A (NO)/3 A (NC)
625 VA, 150 W (NO)
375 VA, 90 W (NC)
10 mA at 5 VDC
Inductive load
0.5 A at 250 VAC, cos
φ
=0.4
1 A at 250 VAC, cos
φ
=0.8
0.8 A at 250 VAC, cos
φ
=0.9
Contact material
Rated carry current
Max. switching voltage
Max. switching current
Max. switching capacity
1 A
250 VA
Min. permissible load
Note: P level:
λ
60=0.1 x 10
--6
operation (with an operating frequency of 120 operations/min.)
CHARACTERISTICS
Contact resistance (See Note 2.)
Operate time (See Note 3.)
Release time (See Note 3.)
Insulation resistance (See Note 4.)
Dielectric strength
100 m
max.
10 ms max.
5 ms max.
1,000 M
min.
4,000 VAC, 50/60 Hz for 1 min between coil and contacts
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
8 kV (1.2 x 50
μ
s)
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours
Destruction: 10 to 55 Hz, 1.5 mm double am litude for 2 hours
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude for 5 minutes
Destruction: 1,000 m/s
2
(approx. 100G)
Malfunction: Energized: 100 m/s
2
(approximately 10G)
Non-energized: 50 m/s
2
(approximately 5G)
Impulse withstand voltage
Vibration resistance
Shock resistance
(This table continues on the next page.)