![](http://datasheet.mmic.net.cn/320000/FSK-S10-5U_datasheet_16338353/FSK-S10-5U_2.png)
2
2
Over-temperature
Thermal shutdown
2
Temperature drift
Hold-up time
Weight
Protection
Parameter
Over-current
Over-voltage
General
Parameter
Efficiency
Isolated Dielectric withstand Input/Output
Input
Parameter
Input voltage
AC input
DC input
Output
Parameter
Set point accuracy
Line regulation
(Low line to high line)
Conditions/Description
Min
Nom
Max
Units
Conditions/Description
Continuous auto recovery
Internal clamping
Min
105%
115%
Nom
Max
135%
140%
145
Units
Conditions/Description
Typical at full load
Min
Nom
73%
Max
Units
Conditions/Description
Min
-2%
Nom
Max
+2%
Units
-1.0%
+1.0%
Load regulation, static
Main output
Aux. outputs
-1.0%
-2.0%
+1.0%
+2.0%
Minimum load
Ripple & noise
1.0%Vout
20 MHz bandwidth
mVpp
0.0
Amps
Continuous operation in a protected state may compromise long-term reliability.
Note 3.
3
Input/FG
Output/FG
3K
2K
0.5K
VAC
VAC
VAC
Agency standards
Case material
Material flammability
MTBF
Operating temperature
Storage temperature
Zn
250k
hours
°C
°C
-10
-20
+60
+70
Humidity
Operating (non-condensing)
Single-output models
20%
90%
90
RH
grams
Isolated Insulation resistance Input/Output (all at 500 VDC)
100M
100M
70M
Ohms
Ohms
Ohms
MIL-HDBK-217F
94 V-0
Designed to meet UL1950, EN60950, CISPR22, CE, CB, FCC class B
Single output models
Note 2. To maintain specified regulation, it is required to have a minimum 10% load on the main output, and a 20% load
on each auxillary output. Under no load conditions, operations will not damage the devices, but all specified
regulation may not be met.
°C
85 264 VAC
110 340 VDC
47
Load regulation, dynamic
Main output
-3.0%
-1.0%
10
+3.0%
+1.0%
ms
0.11
30
60
400
0.21
Hz
Amps
Amps
Line frequency
Input current
Inrush current (cold start)
Leakage current
@110VAC
@220VAC
Amps
Amps
@110VAC
@220VAC
0.5
0.75
mA
mA
@110VAC
@220VAC
Vibration
Impact
10G, 10~55Hz, for 3 minutes
50G on X, Y & Z-axis, for 11ms
Input/FG
Output/FG
www.v-infinity.com
V-INFINITY LLC, 9615 SW Allen Blvd., Suite 103, Beaverton, OR 97005
1-866-372-1258
FSK10 Series AC/DC Converters