![](http://datasheet.mmic.net.cn/210000/FN1393-1-05-11_datasheet_15433861/FN1393-1-05-11_1.png)
IEC inlet filters
FN 390
Versatile filtered power entry module
Approvals
■
Rated currents up to 10A
■
For one or two fuses
■
Fuses 6.3 x 32mm or 5 x 20mm
■
2-pole rocker switch
■
Voltage selector
■
Optional earth line choke (E type)
Typical applications
The FN 390 power entry module combines
an IEC inlet, mains filter with single or
dual-fuse holder, voltage selector and 2-pole
rocker switch. Choosing FN 390 product
line brings you the rapid availability of a
standard filter associated with the necessary
safety acceptances. Standard IEC connector
filters are a practical solution helping you to
pass EMI system approval in a short time.
Multiple options designed to offer you the
desired solution.
■
High conducted attenuation performance,
based on chokes with high saturation
resistance and excellent thermal behavior.
■
Rear or front mounting.
■
Single or dual-fuse holder.
■
USA 6.3 x 32mm or EU 5 x 20mm fuses.
■
2-pole rocker switch.
■
Voltage selector 110-120V / 220-240V.
■
Custom-specific versions are available on
request.
■
Portable electrical and electronic
equipment
■
Consumer goods
■
EDP and office equipment
■
Single-phase power supplies, switch-mode
power supplies
■
Test and measurement equipment
Features and benefits
Technical specifications
Maximum continuous operating voltage:
Operating frequency:
Rated currents:
High potential test voltage:
Protection category:
Temperature range (operation and storage):
Design corresponding to:
Flammability corresponding to:
MTBF @ 40°C/230V (Mil-HB-217F):
250VAC, 50/60Hz
50 to 400Hz
1 to 10A @ 40°C max.
P –> E 2000VAC for 2 sec
P –> N 760VAC for 2 sec
IP40 according to IEC 60529
-25°C to +85°C (25/85/21)
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
UL 94V-2 or better
2,200,000 hours
Voltage selector description:
Function:
Voltage marking:
Series:
Parallel:
Rocker switch description:
Function:
Electrical specifications:
Mechanical life:
Switch ratings:
USA (UL):
Canada (CSA):
Europe (ENEC):
Series/parallel
110-120V
220-240V
2-pole, dark not illuminated
Marking I - 0
Inrush current 51A
6,000 on-off operations according to UL 1054, TV 5
10,000 on-off operations according to ENEC
50,000 cycles
10A, 125VAC; 1/3HP; 10A, 250VAC; 1/2HP
6A, 125VAC; 4A, 250VAC; 1/10HP
10A (4A), 250VAC*
*
Value in () relates to the inductive current charge: cos
γ
= 0.65
Typical electrical schematic
N
E
P
Line
Cx
R
2xL1
2xCy
Load
Cx1
E types
Standard types
N
E
P
Line
Cx
R
2xL1
2xCy
Load
L2