![](http://datasheet.mmic.net.cn/180000/F-MK-2A5-31-25_datasheet_11296539/F-MK-2A5-31-25_1.png)
IEC Inlet Filters F.MH-F.MK-F.ML-F.MM-F.MP-F.MQ-F.MR-F.MS series
With fuse holder, bipolar switch and voltage selector
This series gives a high level of suppression within a compact
enclosure. The IEC 60320 inlet power entry module combines 1 or 2
fuse holders for US and IEC fuses, with a bipolar rocker switch, earth
choke and input voltage selector.
Designed for use in business, consumer, test and medical equipment
for international markets.
Current ratings from 1A to 6A
Comprehensive range of filter performance options
Integral single or twin fuse holder
Optional voltage selector
Optional earth line choke
Horizontal or vertical mounting
Medical versions available
Approvals
Electrical Specifications
Rated voltage (VR): max 250V, 50/60Hz
Rated current (IR):
referred to room temperature = 40°C
Leakage current (IL): at 220V, 50Hz, max value
Voltage test (2S.):
line to ground 3000Vdc or 1800Vac
line to line 1700Vdc
Climatic category:
HPF (25/085/21);
Temperature range: -25°C to +85°C
Bipolar rocker
10(4)A / 250Vac (Rated current),
Switches:
50000 on-off operations;
values in ( ) relate to the inductive current;
inrush current test according to UL 1054 (35A).
Voltage selector:
110-220Vac (F.MH - F.MK - F.ML - F.MM only).
Mechanical Specifications
Manufacture: metal case with built-in power line connector
according to IEC 60320,
fuse holder for 1 fuse (F.MH. - F.ML. - F.MP. - F.MR)
or 2 fuses (F.MK. - F.MM. - F.MQ. - F.MS)
5 x 20mm (IEC) or 6.3 x 32mm (US),
bipolar rocker switch,
voltage selector 110/220Vac (F.MH - F.MK - F.ML
- F.MM only); internal components sealed with
self-extinguishing resin.
Connections: IEC 60320 - Standard plug (INPUT);
faston 6.3 x 0.8mm (OUTPUT);
ground terminal connected to case.
Mounting:
F.MH, F.MK, FML, FMM versions now available in
vertical mounting version - (F.**.***.**.**.010) with
no approvals.
32
▲
■
Filter Range
(example pt no. - F.MH.01A.20.25)
Code
IR
L1
L2
Cx1
Cx2
Cy
lL
R
(A) (mH)
(mH) (F)
(F)
(pF)
(mA)
(M
Ω)
20.- -
2 x 10
2 x 4700
2 x 0.43
01A
24.- - 1
2 x 10
0.22
0.1
2 x 0.003 0.33
30.- -
2 x 22
2 x 4700
2 x 0.43
34.- -
2 x 22
2 x 0.003
21.- -
2 x 2
2 x 4700
2 x 0.43
F.MH. 2A5
25.- - 2.5 2 x 2
0.22
0.1
2 x 0.003 0.33
F.MK.
31.- -
2 x 8
2 x 4700
2 x 0.43
F.MQ.
35.- -
2 x 8
2 x 0.003
F.MS.
22.- -
2 x 1
2 x 4700
2 x 0.43
04A
26.- - 4
2 x 1
0.22
0.1
2 x 0.003 0.33
32.- -
2 x 8
2 x 4700
2 x 0.43
36.- -
2 x 8
2 x 0.003
23.- -
2 x 1
2 x 4700
2 x 0.43
06A
27.- - 6
2 x 1
0.22
0.1
2 x 0.003 0.33
33.- -
2 x 2.5
2 x 4700
2 x 0.43
37.- -
2 x 2.5
2 x 0.003
20.- -
2 x 10
●
2 x 4700
2 x 0.43
01A
24.- - 1
2 x 10 0.65
0.22
0.1
2 x 0.003 0.33
30.- -
2 x 22
2 x 4700
2 x 0.43
34.- -
2 x 22
2 x 0.003
21.- -
2 x 2
●
2 x 4700
2 x 0.43
F.ML. 2A5
25.- - 2.5 2 x 2
0.65
0.22
0.1
2 x 0.003 0.33
F.MM.
31.- -
2 x 8
2 x 4700
2 x 0.43
F.MP.
35.- -
2 x 8
2 x 0.003
F.MR.
22.- -
2 x 1
●
2 x 4700
2 x 0.43
04A
26.- - 4
2 x 1
0.65
0.22
0.1
2 x 0.003 0.33
32.- -
2 x 8
2 x 4700
2 x 0.43
36.- -
2 x 8
2 x 0.003
23.- -
2 x 1
●
2 x 4700
2 x 0.43
06A
27.- - 6
2 x 1
0.65
0.22
0.1
2 x 0.003 0.33
33.- -
2 x 2.5
2 x 4700
2 x 0.43
37.- -
2 x 2.5
2 x 0.003
No approvals, Circuit Diagram D
No approvals, Circuit Diagram C
● Not applicable to FMP,FMR
.010 = Vertical mounting option (addition to standard pt no.)
25 = Rocker switch
26 = Illuminated rocker switch
H = 1 fuse
K = 2 fuses
L = 1 fuse + earth choke
M = 2 fuses + earth choke
P = 1 fuse, single pole switch (no voltage selector)
Q = 2 fuses, single pole switch (no voltage selector)
R = 1 fuse, double pole switch (no voltage selector)
S = 2 fuses, double pole switch (no voltage selector)
▲
■
▲
■
Circuit Diagram:
A
B
D
C