www.vishay.com
124
ETPW
Vishay Roederstein
Document Number 42074
Revision 15-Aug-02
For technical questions, contact eurotant@vishay.com
PERFORMANCE CHARACTERISTICS
1.
Climatic Category :
55/125/56 acc. to IEC
2.
Temperature Range: -
55
°
C up to + 125
°
C with linear
voltage derating to category voltage UC
3.
Rated Voltage, Category Voltage:
3V_ to 50V_;
2V_ to 33V_
4.
Surge Voltage:
1.3 times of rated voltage at + 85
°
C
5.
Reverse Voltage (Temporary):
15% of the rated DC voltage at + 20
°
C
10% of the rated DC voltage at + 55
°
C
5% of the rated DC voltage at + 85
°
C
6.
Rated Capacitance:
0.1
μ
F to 330
μ
F
7.
Capacitance Tolerance :
±
20%,
±
10%,
8.
Leakage Current in
μ
A:
Measured at + 20
°
C after 5
minutes:
≤
0.01 x C
R
x U
R
or 0.5
μ
A, whichever
is greater
9.
Dissipation Factor:
at 120Hz and + 20
°
C
See table
10. Impedance:
Measured at 100kHz and + 20
°
C
See table.
TEST TEMPERATURE
- 55
°
C
+ 20
°
C
+ 85
°
C
+ 125
°
C
C/C <
tan
δ
≤
1.5
μ
F
< 10
μ
F
< 100
μ
F
≥
100
μ
F
- 10%
-
+ 12%
+ 15%
0.04
0.06
0.08
0.10
0.04
0.06
0.08
0.10
0.04
0.06
0.08
0.10
0.06
0.08
0.08
0.10
Leakage current IR
-
≤
0.01 x C
R
x U
R
or 0.5
μ
A
whichever is greater
≤
0.1 x C
R
x U
R
or 10
μ
A
whichever is greater
≤
0.125 x C
R
x U
R
or 12.5
μ
A
whichever is greater*
16. Characteristics at high and low temperatures
(the values shall not exceed the following limits)
TEMPERATURE
+ 50
°
C
+ 85
°
C
+ 125
°
C.
FACTOR
0.7
0.5
0.3
11. Permissible AC Voltage Stress:
The highest
permissible AC voltage for the respective frequency may
be taken from the brochure “General information”.
The values apply for + 20
°
C For higher temperatures,
the values have to be multiplied with the following factors:
Intermediate values can be obtained by linear
interpolation.
For further notes on AC voltage stress: See general
information
12. Service life :
> 300.000 h**
13. Failure percentage:
≤
0.6% within 100.000 h**
14. Failure rate (
λ
):
≤
0.6 10
-7
/h =
≤
60 fit**
15. Failure criteria:
Catastrophic failure : Short circuit or
interruption
Drift failure:
C/C > +5 - 15%
Z > 3 times initial limit value
IR > 5 times initial value + 5
μ
A
** related to UR, + 40
°
C and a circuit resistance of
≥
3
/V
*Measured at category voltage
Resin-Coated, Radial-Leaded