Altera Corporation
4–11
June 2006
Stratix Device Handbook, Volume 2
Selectable I/O Standards in Stratix & Stratix GX Devices
Figure 4–10. SSTL-2 Class II Termination
SSTL-18 Class I & II - EIA/JEDEC Preliminary Standard JC42.3
The SSTL-18 I/O standard is a 1.8-V memory bus standard. This standard
is similar to SSTL-2 and defines input and output specifications for
devices that are designed to operate in the SSTL-18 logic switching range
0.0 to 1.8 V. SSTL-18 requires a 0.9-V VREF and a 0.9-V VTT to which the
for details on SSTL-18 Class I and II termination. Stratix and Stratix GX
devices support both input and output levels.
Figure 4–11. SSTL-18 Class I Termination
Figure 4–12. SSTL-18 Class II Termination
Differential SSTL-2 - EIA/JEDEC Standard JESD8-9A
The differential SSTL-2 I/O standard is a 2.5-V standard used for
applications such as high-speed DDR SDRAM clock interfaces. This
standard supports differential signals in systems using the SSTL-2
Output Buffer
Input Buffer
VTT = 1.25 V
50
Ω
VTT = 1.25 V
50
Ω
25
Ω
Z = 50
Ω
VREF = 1.25 V
Output Buffer
Input Buffer
VTT = 0.9 V
50
Ω
25
Ω
Z = 50
Ω
VREF = 0.9 V
Output Buffer
Input Buffer
VTT = 0.9 V
50
Ω
VTT = 0.9 V
50
Ω
25
Ω
Z = 50
Ω
VREF = 0.9 V