Vishay Siliconix
DG411HS, DG412HS, DG413HS
www.vishay.com
4
Document Number: 72053
S13-1283-Rev. D, 27-May-13
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
For technical questions, contact: pmostechsupport@vishay.com
Notes:
a. Refer to PROCESS OPTION FLOWCHART.
b. Room = 25 °C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f. VIN = input voltage to perform proper function.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
SPECIFICATIONSa
Parameter
Symbol
Test Conditions
Unless Specified
V+ = 15 V, V- = - 15 V
VL = 5 V, VIN = 2.4 V, 0.8 V
f
Temp.b
Typ.c
A Suffix
- 55 °C to 125 °C
D Suffix
- 40 °C to 85 °C
Unit
Min.d
Max.d
Min.d
Max.d
Dynamic Characteristics (Cont’d)
Off Isolatione
OIRR
RL = 50 , CL = 5 pF
f = 1 MHz
Room
- 91
dB
Channel-to-Channel Crosstalke
XTALK
Room
- 88
Source Off Capacitancee
CS(off)
f = 1 MHz
Room
12
pF
Drain Off Capacitancee
CD(off)
Room
12
Channel On Capacitancee
CD(on)
Room
30
Power Supplies
Positive Supply Current
I+
V+ = 16.5 V, V- = - 16.5 V
VIN = 0 or 5 V
Room
Full
0.0001
1
5
1
5
A
Negative Supply Current
I-
Room
Full
- 0.0001
- 1
- 5
- 1
- 5
Logic Supply Current
IL
Room
Full
0.0001
1
5
1
5
Ground Current
IGND
Room
Full
- 0.0001
- 1
- 5
- 1
- 5
SPECIFICATIONSa (for Unipolar Supplies)
Parameter
Symbol
Test Conditions
Unless Specified
V+ = 12 V, V- = 0 V
VL = 5 V, VIN = 2.4 V, 0.8 V
f
Temp.b
Typ.c
A Suffix
- 55 °C to 125 °C
D Suffix
- 40 °C to 85 °C
Unit
Min.d
Max.d
Min.d
Max.d
Analog Switch
Analog Signal Rangee
VANALOG
Full
12
V
Drain-Source On-Resistance
RDS(on)
V+ = 10.8 V, IS = - 10 mA
VD = 3 V, 8 V
Room
Full
49
80
100
80
100
Dynamic Characteristics
Turn-On Time
tON
RL = 300 , CL = 35 pF
VS = 8 V, see figure 2
Room
Hot
95
140
180
140
160
ns
Turn-Off Time
tOFF
Room
Hot
36
70
79
70
74
Break-Before-Make
Time Delay
tD
DG413HS only, VS = 8 V
RL = 300 , CL = 35 pF
Room
60
Charge Injection
Q
Vg = 6 V, Rg = 0 , CL = 1 nF
Room
60
pC
Power Supplies
Positive Supply Current
I+
V+ = 13.2 V, VIN = 0 or 5 V
Room
Hot
0.0001
1
5
1
5
A
Negative Supply Current
I-
Room
Hot
- 0.0001
- 1
- 5
- 1
- 5
Logic Supply Current
IL
Room
Hot
0.0001
1
5
1
5
Ground Current
IGND
Room
Hot
- 0.0001
- 1
- 5
- 1
- 5