www.ittcannon.com
363
Dimensions are shown in inches (millimeters).
Dimensions subject to change.
Environmental D
D*D
Contact Crimping Information
Assembly Instructions
Crimp Type Contacts
Contact
Size
Contact
Size
AWG
Plastic Insertion/Extraction
Part No.
Description
Plastic Extraction
Part No.
Description
CBT-646
Machine Crimp Rage: 1300 + per hour
Power Requirements:
Products: Most ITT Cannon Commercial and Aero-
space closed-barrel contacts, wire sizes 30 thru 12
AWG. See connector line for part numbers.
Electrical = 115 Vac, 60 Hz, 5A
Pneumatic = 85 psi, 2 cu. ft. per min.
CIET-20HD
Contact
Size
AWG
Crimp Tool
Part No.
Description
Locator
M22520/1-01
Hand Crimp Tools
Wire Stripping-
Machined Contacts
Contact Crimping
Contact Extraction
Contact Insertion
Insertion/Extraction Tools
Semi-Automatic Crimp Machines
M22520/2-01
Part No.
Description
Wire Size
Accom.
Standard Finish
Pin
20
20, 22, 24
20
20, 22, 24
20
A
Min.
Max.
.188 (4.78)
.208 (5.28)
A
20, 22, 24
995-0001-584
995-0001-585
M22520/2-01
M22520/1-01
995-0001-604
995-0001-244
M22520/2-08
TH25
980-2000-426
CIET-20HD
CET-20-11
323-7010-000
330-5291-015
031-1007-000
330-5291-079
031-1007-042
Socket
Military Finish
Pin
Socket
The CBT-646, Vibra-Bowl Crimper is a pneumat-
ically powered, electoronically controlled machine. It
is designed to semi-automatically crimp closed
barrel, machined contacts, as used in the aerospace
and commercial industries. The machine will ac-
commodate wire sizes 30 thru 12 AWG. The
CBT-646 is actuated automatically upon insertion
of a pre-stripped stranded or single conductor wire.
The CBT-646 meets all Mil. Spec. requirements for
crimping closed barrel contacts.
1. Cut wires to length. Strip insulation per above illustration. Check
for broken or frayed wires.
4. To be sure contact is locked securely, pull back lightly on wire.
Repeat for balance of contacts working row by row across the
insulator.
5. Place wire into extraction tool tip.
6. Insert tool tip into contact cavity until tip bottoms against contact
shoulder, releasing tines. Hold wires against tool with finger and
remove tool and contact. Repeat for balance of contacts.
2. Insert contact and wires into poper crimp tool (and locator, if
required). Crimp contact to wires. Inspect crimp.
3. Center wired contact in groove of insertion tool with tool tip
butting contact shoulder. Insert contact into cavity until a positive
stop is felt. Inspection insertion.