CDC330
CLOCK DRIVER
WITH 3-STATE OUTPUTS
SCAS329A – OCTOBER 1993 – REVISED MARCH 1994
2–2
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
logic symbol
logic diagram (positive logic)
22
1A
EN
24
2Q1
5
2Q2
8
2Q3
17
2Q4
19
1Y1
2
1Y2
3
1Y3
23
3Y1
10
3Y2
11
3Y3
14
7
EN
6
PR
20
13
3A
EN
15
T
1OE
2OE
3OE
2A
PRE
This symbol is in accordance with ANSI/IEEE Std 91-1984
and IEC Publication 617-12.
2
1Y1
3
1Y2
23
1Y3
5
2Q1
8
2Q2
17
2Q3
19
2Q4
10
3Y1
11
3Y2
14
3Y3
T
24
22
6
7
20
15
13
R
1OE
2OE
2A
PRE
3OE
3A
1A
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
Input voltage range, V
I
(see Note 1)
Voltage range applied to any output in the disabled or power-off state, V
O
Current into any output in the low state, I
O
Input clamp current, I
IK
(V
I
< 0)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output clamp current, I
OK
(V
O
< 0)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–0.5 V to 7 V
–0.5 V to 7 V
–0.5 V to 5.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . .
96 mA
–18 mA
–50 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–65
°
C to 150
°
C
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.