![](http://datasheet.mmic.net.cn/Intersil/CD22M3494MQZ96_datasheet_96694/CD22M3494MQZ96_5.png)
5
FN2793.7
January 16, 2006
Setup Time
CS to STROBE
tCS
10
-
ns
DATA-IN to STROBE
tDS
10
-
ns
ADDRESS to STROBE
tAS
10
-
ns
Hold Time
STROBE to CS
tCH
10
-
ns
ADDRESS to CS
10
-
ns
STROBE to DATA-IN
tDH
20
-
ns
STROBE to ADDRESS
tAH
10
-
ns
DATA-IN to CS
20
-
ns
Pulse Width
STROBE
tSPW
20
-
ns
RESET
tRPW
20
-
ns
RESET Turn-OFF to Output Delay
tPHZ
-
70
100
ns
NOTES:
2. Operation of VIH at 2.4V or VIL at 0.8V will result in much higher supply current (IDD) than for logic inputs equal to VDD or VSS respectively.
3. Reset IIH < 20A, Reset = VIH.
4. At 25
°C Limit is ±100nA.
Electrical Specifications
TA = 25°C, VSS = 0V, VEE = 0V, VDD = 14V, RL = 1k || 50pF, Unless Otherwise Specified. (Continued)
PARAMETER
SYMBOL
TEST CONDITIONS
MIN
TYP
MAX
UNITS
CD22M3494