CD22101, CD22102
Absolute Maximum Ratings
Thermal Information
Maximum Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . 175
o
C
Maximum Junction Temperature (Plastic Package) . . . . . . . . 150
o
C
Maximum Storage Temperature Range . . . . . . -65
o
C
≤
T
A
≤
150
o
C
Maximum Lead Temperature (Soldering 10s). . . . . . . . . . . . . 300
o
C
Supply Voltage (V
DD
) (Referenced to V
SS
Terminal) . . . .-0.5 to 20V
Input Voltage (All Inputs) . . . . . . . . . . . . . . . . . . . -0.5 to V
DD
+0.5V
Supply Voltage Range
For T
A
= Full Package Temperature Range. . . . . . . . . . . . . . 3V to 18V
Input Current (Any One Input) (Note 1)
. . . . . . . . . . . . . . . . . . .±
10mA
Power Dissipation
For T
A
= -40
o
C to 60
o
C (Package Type E) . . . . . . . . . . . . 500mW
For T
A
= 60
o
C to 85
o
C
Package Type E). . . . . . . . Derate Linearly 12mW/
o
C to 200mW
For T
A
= -55
o
C to 100
o
C (Package Type D, F) . . . . . . . . . 500mW
For T
A
= 100
o
C to 125
o
C
(Package Type D, F) . . . . . Derate Linearly 12mW/
o
C to 200mW
Device Dissipation per Output Transistor
For T
A
= Full Package Temperature Range (All Types) . . . . . 100mW
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation
of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Operating Conditions
Temperature Range
Package Type D, F. . . . . . . . . . . . . . . . . . . . . -55
o
C
≤
T
A
≤
125
o
C
Package Type E. . . . . . . . . . . . . . . . . . . . . . . . -40
o
C
≤
T
A
≤
85
o
C
Electrical Specifications
Values at -55
o
C, 25
o
C, 125
o
C Apply to D, F, H Packages
Values at -40
o
C, 25
o
C, 85
o
C Apply to E Package
PARAMETER
SYMBOL
TEST CONDITIONS
-55
o
C
-40
o
C
85
o
C
125
o
C
25
o
C
UNITS
FIGURE V
DD
(V)
MAX
MAX
MAX
MAX
MIN
TYP
MAX
STATIC CROSSPOINTS
Quiescent Device
Current
I
DD
(Max)
1
5
5
5
150
150
-
0.04
5
μ
A
1
10
10
10
300
300
-
0.04
10
μ
A
1
15
20
20
600
600
-
0.04
20
μ
A
1
20
100
100
3000
3000
-
0.08
100
μ
A
On Resistance
R
ON
(Max) Any Switch
V
IS
= 0 to
V
DD
14
5
475
500
725
800
-
225
600
15
10
135
145
205
230
-
85
180
-
12
100
110
155
175
-
75
135
16
15
70
75
110
125
-
65
95
ON
Resistance
R
ON
Between Any Two
Switches
5
-
-
-
-
-
25
-
10
-
-
-
-
-
10
-
12
-
-
-
-
-
8
-
15
-
-
-
-
-
5
-
OFF Leakage Current
I
L
(Max)
All Switches
OFF, V
IS
= 18V
4
18
±
1000
-
±
1
±
100
(Note 2)
nA
STATIC CONTROLS
Input Low Voltage
V
IL
(Max)
OFF Switch I
L
< 0.2
μ
A
5
1.5
-
-
1.5
V
10
3
-
-
3
V
15
4
-
-
4
V
Input High Voltage
V
IH
(Min)
ON Switch See R
ON
Characteristic
5
3.5
3.5
-
-
V
10
7
7
-
-
V
15
11
11
-
-
V
Input Current
I
IN
(Max)
Any Control
V
IN
= 0, 18V
2
18
±
0.1
±
0.1
±
1
±
1
-
±
10
-5
±
0.1
μ
A
NOTES:
1. Maximum current through transmission gates (switches) = 25mA.
2. Determined by minimum feasible leakage measurement for automatic testing.