ADDC02808PB–SPECIFICATIONS
ELECTRICAL CHARACTERISTICS
–55
8
C to +90
8
C; all temperatures are case and T
C
is the temperature measured at the center of the package bottom.)
Case
Temp
Test
Level
ADDC02808PB
Min
Typ
Parameter
Conditions
Max
Units
INPUT CHARACTERISTICS
Steady State Operating Input Voltage Range
1
Abnormal Operating Input Voltage Range
(Per MIL-STD-704D)
Input Overvoltage Shutdown
No Load Input Current
Disabled Input Current
Full
VI
I
O
= 1.25 A to 25 A Pulsed
18
28
40
V
Full
+25
°
C
+25
°
C
+25
°
C
VI
I
VI
VI
I
O
= 1.25 A to 25 A Pulsed
16
50
50
55
90
2
V
V
mA
mA
52.5
45
1
OUTPUT CHARACTERISTICS
2, 3
Output Voltage (V
O
)
+25
°
C
Full
Full
+25
°
C
+25
°
C
+25
°
C
Full
+25
°
C
+25
°
C
+25
°
C
I
VI
VI
VI
VI
I
VI
V
V
I
I
O
= 1.25 A to 25 A, V
IN
= 18 V to 40 V dc
I
O
= 1.25 A to 25 A, V
IN
= 18 V to 40 V dc
I
O
= 1.25 A to 20 A, V
IN
= 16 V to 50 V dc
I
O
= 25 A Pulsed, V
IN
= 18 V to 40 V dc
V
IN
= 28 V dc, I
O
= 1.25 A to 25 A Pulsed
I
O
= 25 A, 5 kHz – 2 MHz BW
V
IN
= 18 V to 40 V dc, Pulsed
I
O
= 25 A, Open Remote Sense Connection
V
O
= 90% V
OUT
Nom
7.92
7.84
7.84
8.00
8.08
8.16
8.16
5
10
30
25
V
V
V
mV
mV
mV p-p
A
% V
O
nom
% I
O
max
A
Line Regulation
Load Regulation
Output Ripple/Noise
4
Output Current (I
O
)
5
Output Overvoltage Protection
Output Current Limit
Output Short Circuit Current
1
2.5
10
1.25
125
130
40
ISOLATION CHARACTERISTICS
Isolation Resistance
+25
°
C
I
Input to Output or Any Pin to Case at 500 V dc
100
M
DYNAMIC CHARACTERISTICS
4
Step Changes In Load (min to max)
Step Changes In Load (max to min)
+25
°
C
I
(Reference Section Entitled “Transient Response”)
(Reference Section Entitled “Response at End
of Pulse”)
I
O
= 25 A, From Inhibit High to Status High
Soft Start Turn-On Time
+25
°
C
I
6
10
ms
THERMAL CHARACTERISTICS
Efficiency
+25
°
C
Min
Max
+25
°
C
Min
Max
+90
°
C
I
VI
VI
I
VI
VI
V
I
O
= 12.5 A
I
O
= 12.5 A
I
O
= 12.5 A
I
O
= 25 A
I
O
= 25 A
I
O
= 25 A
I
O
= 25 A
77.5
77.5
76
73.5
73.5
71
80
%
%
%
%
%
°
C
76
Hottest Junction Temperature
5
110
CONTROL CHARACTERISTICS
Clock Frequency
ADJUST (Pin 3) V ADJ
STATUS (Pin 4)
V
OH
V
OL
V
AUX
(Pin 5)
V
O
(nom)
INHIBIT (Pin 6)
V
IL
I
IL
V
I
(Open Circuit)
SYNC (Pin 7)
6
V
IH
I
IH
I
SHARE
(Pin 8)
TEMP (Pin 9)
Full
+25
°
C
VI
I
I
O
= 2 A
0.85
3.1
0.99
3.3
MHz
V
3.2
+25
°
C
+25
°
C
I
I
I
OH
= 400
μ
A
I
OL
= 1 mA
2.4
4.0
0.15
V
V
0.7
+25
°
C
I
I
AUX
= 5 mA, Load Current = 12.5 A
14.65 15.15
15.65
V
+25
°
C
+25
°
C
+25
°
C
I
I
I
0.5
1.2
15
V
mA
V
V
IL
= 0.5 V
+25
°
C
+25
°
C
+25
°
C
+25
°
C
I
I
I
V
4.0
V
μ
A
V
V
V
IH
= 7.0 V
I
O
= 20 A
175
2.65
2.45
2.55
3.90
NOTES
1
50 V dc upper limit rated for transient condition of up to 50 ms. 16 V dc lower limit rated for continuous operation during emergency condition. Steady state and
abnormal input voltage range require source impedance sufficient to insure input stability at low line. See sections entitled System Instability Considerations and Input
Voltage Range.
2
Measured at the remote sense points.
3
Unit regulates output voltage to zero load; tests performed at low continuous load and 200 W pulsed load.
4
C
LOAD
= 1,000
μ
F. Output ripple/noise measured at converter output; may be smaller at external load capacitance. Unit is stable for C
LOAD
ranging from 500
μ
F to
4,000
μ
F.
5
Refer to section entitled “Pulse Output Power vs. Pulse Length” for more information.
6
Unit has internal pull-down; refer to section entitled Pin 7 (SYNC).
Specifications subject to change without notice.
REV. A
–2–
(T
C
= +25
8
C, V
IN
= 28 V dc
6
0.5 V dc, unless otherwise noted; full temperature range is