![](http://datasheet.mmic.net.cn/310000/ADDC02808PB_datasheet_16240567/ADDC02808PB_3.png)
ADDC02808PB
REV. A
–3–
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Therefore, proper ESD precautions are recommended to avoid performance degradation or loss
of functionality.
ABSOLUTE MAXIMUM RATINGS*
INHIBIT . . . . . . . . . . . . . . . . . . . . . . . . . . 50 V dc, –0.5 V dc
SYNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.0 V dc, –0.5 V dc
I
SHARE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 V dc, –0.5 V dc
TEMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 V dc, –0.3 V dc
Common-Mode Voltage, Input to Output . . . . . . . . . 500 V dc
Lead Soldering Temp (10 sec) . . . . . . . . . . . . . . . . . . . +300
°
C
Storage Temperature . . . . . . . . . . . . . . . . . . –65
°
C to +150
°
C
Maximum Junction Temperature . . . . . . . . . . . . . . . . +150
°
C
Maximum Case Operating Temperature . . . . . . . . . . . +125
°
C
*Absolute maximum ratings are limiting values, to be applied individually, and
beyond which the serviceability of the circuit may be impaired. Functional
operability under any of these conditions is not necessarily implied. Exposure of
absolute maximum rating conditions for extended periods of time may affect
device reliability.
ORDERING GUIDE
Operating
Temperature
Range (Case)
Device
Description
ADDC02808PBKV
ADDC02808PBTV
5962-9763401HXC
(ADDC02808PBTV/QMLH)
–40
°
C to +85
°
C
–55
°
C to +90
°
C
–55
°
C to +125
°
C Hermetic Package
Hermetic Package
Hermetic Package
EXPLANATION OF TEST LEVELS
Test Level
I
–
II
–
100% production tested.
100% production tested at +25
°
C, and sample tested at
specified temperatures.
Sample tested only.
Parameter is guaranteed by design and characterization
testing.
Parameter is a typical value only.
All devices are 100% production tested at +25
°
C. 100%
production tested at temperature extremes for military
temperature devices; guaranteed by design and charac-
terization testing for industrial devices.
III –
IV –
V
VI –
–
PIN FUNCTION DESCRIPTIONS
Pin
No.
Name
Function
1
–SENSE
Feedback loop connection for remote sensing
output voltage. Must always be connected to
output return for proper operation.
Feedback loop connection for remote sensing
output voltage. Must always be connected to
+V
OUT
for proper operation.
Adjusts output voltage setpoint.
Indicates output voltage is within
±
5% of
nominal. Active high referenced to –SENSE
(Pin 1).
Low level dc auxiliary voltage supply refer-
enced to input return (Pin 10).
Power Supply Inhibit. Active low and refer-
enced to input return (Pin 10).
Clock synchronization input for multiple
units; referenced to input return (Pin 10).
Current share pin which allows paralleled
units to share current typically within
±
5% at
full load; referenced to input return (Pin 10).
Case temperature indicator and temperature
shutdown override; referenced to input return
(Pin 10).
Input Return.
+28 V Nominal Input Bus.
+8 V dc Output.
+8 V dc Output.
+8 V dc Output.
RETURN Output Return.
RETURN Output Return.
RETURN Output Return.
2
+SENSE
3
4
ADJUST
STATUS
5
V
AUX
6
INHIBIT
7
SYNC
8
I
SHARE
9
TEMP
10
11
12
13
14
15
16
17
–V
IN
+V
IN
+V
OUT
+V
OUT
+V
OUT
PIN CONFIGURATION
1
11
12
17
TOP
VIEW
WARNING!