ADCMP350/ADCMP352/ADCMP354/ADCMP356
Rev. A | Page 3 of 12
SPECIFICATIONS
VCC = Full operating range, TA = –40°C to +125°C, unless otherwise noted.
Table 2.
Parameter
Min
Typ
Max
Unit
Test Conditions/Comments
SUPPLY
VCC Operating Voltage Range
2.25
5.5
V
VIN Operating Voltage Range
0
22
V
Supply Current
10
15
A
VIN THRESHOLD RISING
0.579
0.6
0.621
V
VCC = 3.3V, TA = 40°C to +85°C
0.579
0.6
0.624
V
VCC = 3.3V, TA = 40°C to +125°C
VIN THRESHOLD FALLING
0.564
0.585
0.606
V
VCC = 3.3V, TA = 40°C to +85°C
0.564
0.585
0.609
V
VCC = 3.3V, TA = 40°C to +125°C
INPUT BIAS CURRENT
10
nA
VIN = 0.6 V
170
A
VIN = 22 V
THRESHOLD TEMPERATURE COEFFICIENT
30
ppm/°C
VIN TO OUT DELAY
5
s
VIN = VTH to (VTH 100 mV)
OUT VOLTAGE LOW
0.4
V
VIN < VTH min, ISINK = 1.2 mA
OUT VOLTAGE HIGH
0.8 × VCC
V
VIN > VTH max, ISOURCE = 500 A,
Push-pull only
OUTPUT RISE TIME
30
ns
Cout = 15 pF
OUTPUT FALL TIME
45
ns
Cout = 15 pF
OUTPUT LEAKAGE CURRENT
1
A
OUT = 22 V, open drain only