![](http://datasheet.mmic.net.cn/Analog-Devices-Inc/AD9117BCPZRL7_datasheet_100548/AD9117BCPZRL7_39.png)
Data Sheet
AD9114/AD9115/AD9116/AD9117
Rev. C | Page 39 of 52
Register
Address
Bit
Name
Description
Memory R/W
0x12
7
CALRSTQ
0 (default): no action.
1: clears CALSTATQ.
6
CALRSTI
0 (default): no action.
1: clears CALSTATI.
4
CALEN
0 (default): no action.
1: initiates device self-calibration.
3
SMEMWR
0 (default): no action.
1: writes to static memory (calibration coefficients).
2
SMEMRD
0 (default): no action.
1: reads from static memory (calibration coefficients).
1
UNCALQ
0 (default): no action.
1: resets Q DAC calibration coefficients to default (uncalibrated).
0
UNCALI
0 (default): no action.
1: resets I DAC calibration coefficients to default (uncalibrated).
CLKMODE
0x14
7:6
CLKMODEQ[1:0]
Depending on CLKMODEN bit setting, these two bits reflect the phase relationship
If CLKMODEN = 0, read only; reports the clock phase chosen by the retime.
If CLKMODEN = 1, read/write; value in this register sets Q clock phases; force if
needed to better synchronize the DACs (see t
he Retimer section).
4
Searching
Datapath retimer status bit.
0 (default): clock relationship established.
1: indicates that the internal datapath retimer is searching for clock relationship
(device output is not usable while this bit is high).
3
Reacquire
Edge triggered, 0 to 1 causes the retimer to reacquire the clock relationship.
2
CLKMODEN
0 (default): CLKMODEI/CLKMODEQ values computed by the two retimers and read
back in CLKMODEI[1:0] and CLKMODEQ[1:0].
1: CLKMODE values set in CLKMODEI[1:0] override both I and Q retimers.
1:0
CLKMODEI[1:0]
Depending on CLKMODEN bit setting, these two bits reflect the phase relationship
If CLKMODEN = 0, read only; reports the clock phase chosen by the retimer.
If CLKMODEN = 1, read/write; value in this register sets I clock phases; force if
needed to better synchronize the DACs (see t
he Retimer section).
Version
0x1F
7:0
Version[7:0]
Hardware version of the device. This register is set to 0x0A for the latest version of
the device.