Product Structure
Version
E
Europe / Asia (cylindrical thread G)
A
America (conical thread NPT)
Certificates
B EEx ia IIC T6, Zone 1 (only in FRG)/ATEX II 2 G
J
FM, IS Class I, II, III, Division 1 Groups A-G (for Version A only)
Q CSA, IS Class I, II, III Division 1 Groups A-G (for Version A only)
T
TIIS Ex ia II C T6
Communication
F without
B 4
…
20 mA, HART protocol
P PROFIBUS-PA
Product designation
Process Connection Versions with G or NPT
Threads
FMU 130: G 1
1
/
or 1
1
/
NPT
Range: max. 2 m/6.6 ft (solids) or
max. 4 m/13.1 ft (liquids)
FMU 131: G 2
or 2 NPT
Range: max. 3.5 m/11.5 ft (solids) or
max. 7 m/23 ft (liquids)
Enter "Y" for special certificates or communication
mode.
Version
E
Europe / Asia (cylindrical thread G)
A
America (conical thread NPT)
Certificates
A Standard
N CSA General Purpose (for Version A only)
Communication
A 4
…
20 mA, 2-wire, without communication
C 4
…
20 mA, 2-wire, HART protocol
D Power supply 18
…
36 V
DC
, 50/60 Hz, 4-wire, without communication
E Power supply 18
…
36 V
, 50/60 Hz, 4-wire, HART protocol
F Power supply 180
…
250 V
AC
, 50/60 Hz, 4-wire, without communication
G Power supply 180
…
250 V
AC
, 50/60 Hz, 4-wire, HART protocol
J Power supply 90
…
127 V
AC
, 50/60 Hz, 4-wire, without communication
K Power supply 90
…
127 V
AC
, 50/60 Hz, 4-wire, HART protocol
P PROFIBUS-PA
Product designation
Process Connection Versions with G or NPT
Threads
FMU 230: G 1
1
/
or 1
1
/
NPT
Range: max. 2 m/6.6 ft (solids) or
2-wire: max. 4 m/13.1 ft (liquids)
4-wire: max. 5 m/16.4 ft (liquids)
FMU 231: G 2
or 2 NPT
Range: max. 3.5 m/11.5 ft (solids) or
2-wire: max. 7 m/23 ft (liquids)
4-wire: max. 8 m/26.2 ft (liquids)
Enter "Y" for special certificates or communication
mode.
Certificates
A Standard
F
Dust Ex Zone 10 / ATEX II 1/3 D
M FM Class II, Division 1, Groups E, F, G
N CSA General Purpose
R CSA Class II, Division 1, Groups E, F, G
Power Supply / Communication
D Power supply 18
…
36 V
DC
, 50/60 Hz, 4-wire, without communication
E Power supply 18
…
36 V
DC
, 50/60 Hz, 4-wire, HART protocol
F Power supply 180
…
250 V
AC
, 50/60 Hz, 4-wire, without communication
G Power supply 180
…
250 V
AC
, 50/60 Hz, 4-wire, HART protocol
J Power supply 90
…
127 V
AC
, 50/60 Hz, 4-wire, without communication
K Power supply 90
…
127 V
AC
, 50/60 Hz, 4-wire, HART protocol
P PROFIBUS-PA 2-wire (in preparation)
Product designation
Process Connection Versions:
Flange DN 100 / PN 16
Flange ANSI 4" / 150 psi
Flange JIS 16K 100
Range: up to 7 m/23 ft (solids) or
max. 15 m/49.2 ft (liquids)
Enter "9" for special display or housing versions.
Housing / Cable Entry
1
Plastic housing IP 67, Pg 16 IP 67
(with FMU 130, 131, 230, 231 for Version E only)
2
Plastic housing NEMA 6, NPT
/
"
3
Plastic housing IP 67, M 20x1.5 (with FMU 130, 131, 230, 231 for Version E only)
4
Plastic housing IP 67, G
/
2
A (with FMU 130, 131, 230, 231 for Version E only)
5
Plastic housing, M12 PROFIBUS-PA connector
Display
1
Without plug-in display
2
With plug-in display
Product designation
FMU 130 / 131 (2-wire, Ex)
FMU 230 / 231 (2-wire not Ex, 4-wire)
FMU 232 (4-wire)
For all instrument versions
11