Philips Semiconductors
Product specification
PCK2010RA
CK98R (100/133MHz) RCC spread spectrum
system clock generator
2001 Apr 02
10
AC CHARACTERISTICS (Continued)
TEST CONDITIONS
LIMITS
SYMBOL
PARAMETER
TEST CONDITIONS
Tamb = 0 to +70 °C
UNIT
NOTES
SYMBOL
PARAMETER
Measurement loads
(lumped)
Measure points
MIN
TYP
MAX
UNIT
NOTES
THPOFFSET
CPUCLK to 3V66 CLK,
CPU leads
CPU@20 pF,
3V66@30 pF
CPU@1.25 V,
3V66@1.5 V
0.0
0.45
1.5
ns
1
THPOFFSET
3V66 CLK to PCICLK,
3V66 leads
3V66@30 pF,
PCI@30 pF
3V66@1.5 V,
PCI@1.5 V
1.5
2.0
3.5
ns
1
THPOFFSET
CPUCLK to IOAPIC,
CPU leads
CPU@20 pF,
IOAPIC@20 pF
3CPU@1.25 V,
IOAPIC@1.25 V
1.5
2.4
4.0
ns
1
THPOFFSET
CPUCLK to PCICLK ,
CPU leads
CPU@20 pF
PCI@30 pF
CPU@1.25 V
PCI@1.5 V
1.5
2.7
4.0
ns
NOTES:
1. Output drivers must have monotonic rise/fall times through the specified VOL/VOH levels.
2. Period, jitter, offset and skew measured on rising edge @1.25 V for 2.5 V clocks and @ 1.5 V for 3.3 V clocks.
3. The PCICLK is the CPUCLK divided by four at CPUCLK = 133 MHz. The 3V66 CLK is internal VCO frequency divided by three at
CPUCLK = 100 MHz.
4. 3V66 CLK is internal VCO frequency divided by two at CPUCLK = 133 MHz. The 3V66 CLK is internal VCO frequency divided by three at
CPUCLK = 100 MHz.
5. THKH is measured at 2.0 V for 2.5 V outputs, 2.4 V for 3.3 V outputs as shown in Figure 4.
6. THKL is measured at 0.4 V for all outputs as shown in Figure 4.
7. The time is specified from when VDDQ achieves its nominal operating level (typical condition VDDQ = 3.3 V) until the frequency output is
stable and operating within specification.
8. THRISE and THFALL are measured as a transition through the threshold region VOL = 0.4 V and VOH = 2.4 V for 3 V outputs (1 mA) JEDEC
specification. THRISE and THFALL are measured as a transition through the threshold region VOL = 0.4 V and VOH = 2.0 V for 2.5 V outputs
(1 mA) JEDEC specification.
9. The average period over any 1
s period of time must be greater than the minimum specified period.
10. Calculated at minimum edge-rate (1V/ns) to guarantee 45/55% duty-cycle. Pulse width is required to be wider at faster edge-rate to ensure
duty-cycle specification is met.
11. Output (see Figure 5 for measure points).