2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text
of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a
specific exemption has been obtained.
3. REQUIREMENTS
3.1 Item requirements. The individual item performance requirements for device classes D, E, G, H, and K shall be in
accordance with MIL-PRF-38534. Compliance with MIL-PRF-38534 may include the performance of all tests herein or as
designated in the device manufacturer's Quality Management (QM) plan or as designated for the applicable device class.
Therefore, the tests and inspections herein may not be performed for the applicable device class (see MIL-PRF-38534).
Furthermore, the manufacturer may take exceptions or use alternate methods to the tests and inspections herein and not
perform them. However, the performance requirements as defined in MIL-PRF-38534 shall be met for the applicable device
class.
3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as
specified in MIL-PRF-38534 and herein.
3.2.1 Case outline(s). The case outline(s) shall be in accordance with 1.2.4 herein and figure 1.
3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2.
3.2.3 Truth table(s). The truth table(s) shall be as specified on figure 3.
3.2.4 Timing diagrams. The timing diagram(s) shall be specified on figures 4, 5, and 6.
3.2.5 Block diagram. The block diagram shall be as specified on figure 7.
3.2.6 Output load circuit. The output load circuit shall be as specified on figure 8.
3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are
as specified in table I and shall apply over the full specified operating temperature range.
3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical
tests for each subgroup are defined in table I.
3.5 Programming procedure. The programming procedure shall be as specified by the manufacturer and shall be available
upon request.
3.6 Marking of Device(s). Marking of device(s) shall be in accordance with MIL-PRF-38534. The device shall be marked
with the PIN listed in 1.2 herein. In addition, the manufacturer's vendor similar PIN may also be marked.
3.7 Data. In addition to the general performance requirements of MIL-PRF-38534, the manufacturer of the device
described herein shall maintain the electrical test data (variables format) from the initial quality conformance inspection group
A lot sample, for each device type listed herein. Also, the data should include a summary of all parameters manually tested,
and for those which, if any, are guaranteed. This data shall be maintained under document revision level control by the
manufacturer and be made available to the preparing activity (DSCC-VA) upon request.