TLE206x, TLE206xA, TLE206xB, TLE206xY
EXCALIBUR JFET-INPUT HIGH-OUTPUT-DRIVE
POWER OPERATIONAL AMPLIFIERS
SLOS193A – FEBRUARY 1997 – REVISED MARCH 1998
19
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
TLE2061M electrical characteristics at specified free-air temperature, VCC± = ±15 V (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
TA
TLE2061M ,TLE2061AM
TLE2061BM
UNIT
TA
MIN
TYP
MAX
TLE2061M
25
°C
0.6
3
TLE2061M
Full range
6
VIO
Input offset voltage
TLE2061AM
25
°C
0.5
1.5
mV
VIO
Input offset voltage
TLE2061AM
Full range
3.6
mV
TLE2061BM
25
°C
0.3
0.5
TLE2061BM
Full range
1.7
αVIO
Temperature coefficient of input offset
voltage
VIC = 0,
RS = 50
Full range
6
V/°C
Input offset voltage long-term drift
(see Note 4)
25
°C
0.04
V/mo
IIO
Input offset current
25
°C
2
pA
IIO
Input offset current
Full range
20
nA
IIB
Input bias current
25
°C
4
pA
IIB
Input bias current
Full range
40
nA
VICR
Common mode input voltage range
25
°C
– 11 to 13
– 12 to 16
V
VICR
Common-mode input voltage range
Full range
– 11 to 13
V
RL =10k
25
°C
13
13.7
VOM
Maximum positive peak output voltage
RL = 10 k
Full range
12.5
V
VOM +
Maximum ositive eak out ut voltage
swing
RL = 600
25
°C
12.5
13.2
V
RL = 600
Full range
12
RL =10k
25
°C
–13
– 13.7
VOM
Maximum negative peak output voltage
RL = 10 k
Full range
– 12.5
V
VOM –
Maximum negative eak out ut voltage
swing
RL = 600
25
°C
– 12.5
–13
V
RL = 600
Full range
–12
VO = ± 10 V,
25
°C
30
230
VO ± 10 V,
RL = 10 k
Full range
20
AVD
Large-signal differential voltage
VO = 0 to 8 V,
25
°C
25
100
V/mV
AVD
Large signal differential voltage
amplification
VO 0 to 8 V,
RL = 600
Full range
7
V/mV
VO = 0 to – 8 V,
25
°C
3
25
VO
0 to
8 V,
RL = 600
Full range
1
ri
Input resistance
25
°C
1012
ci
Input capacitance
25
°C
4
pF
zo
Open-loop output impedance
IO = 0
25
°C
280
CMRR
Common mode rejection ratio
VIC = VICRmin,
25
°C
72
90
dB
CMRR
Common-mode rejection ratio
VIC VICRmin,
RS = 50
Full range
65
dB
kSVR
Supply-voltage rejection ratio
VCC
± = ±5 V to ±15 V,
25
°C
75
93
dB
kSVR
yg
j
(
VCC± /VIO)
CC
±
,
RS = 50
Full range
65
dB
Full range is – 55
°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated