TLE2061M electrical characteristics at specified free-air temperature, VCC± = ±5 V (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
TA
TLE2061M
TLE2061AM
TLE2061BM
UNIT
TA
MIN
TYP
MAX
TLE2061M
25
°C
0.8
3.1
TLE2061M
Full range
6
VIO
Input offset voltage
TLE2061AM
25
°C
0.6
2.6
mV
VIO
Input offset voltage
TLE2061AM
Full range
4.6
mV
TLE2061BM
25
°C
0.5
1.9
TLE2061BM
VIC = 0,
RS = 50
Full range
3.1
αVIO
Temperature coefficient of input offset voltage
VIC = 0,
RS = 50
Full range
6
V/°C
Input offset voltage long-term drift (see Note 4)
25
°C
0.04
V/mo
IIO
Input offset current
25
°C
1
pA
IIO
Input offset current
Full range
15
nA
IIB
Input bias current
25
°C
3
pA
IIB
Input bias current
Full range
30
nA
VICR
Common-mode input voltage range
25
°C
1.6
to
4
2
to
6
V
VICR
Common-mode input voltage range
Full range
1.6
to
4
V
RL = 10 k
25
°C
3.5
3.7
RL = 10 k
Full range
3
VOM + Maximum positive peak output voltage swing
RL = 600
25
°C
2.5
3.6
V
VOM + Maximum positive peak output voltage swing
RL = 600
Full range
2
V
RL = 100
25
°C
2.5
3.1
RL = 100
Full range
2
RL = 10 k
25
°C
3.5
3.9
RL = 10 k
Full range
3
VOM
Maximum negative peak
FK and JG
RL = 600
25
°C
2.5
3.5
V
VOM
Maximum negative peak
output voltage swing
FK and JG
packages
RL = 600
Full range
2
V
output voltage swing
D and P
RL = 100
25
°C
2.5
2.7
D and P
packages
RL = 100
Full range
2
VO = ± 2.8 V,
RL = 10 k
25
°C
15
80
VO = ± 2.8 V,
RL = 10 k
Full range
2
VO = 0 to 2.5 V, RL = 600
25
°C
1
65
FK and JG
VO = 0 to 2.5 V, RL = 600
Full range
0.5
AVD
Large-signal differential
FK and JG
packages
VO = 0 to 2.5 V,RL = 600
25
°C
1
16
V/mV
AVD
Large-signal differential
voltage amplification
packages
VO = 0 to 2.5 V,RL = 600
Full range
0.5
V/mV
voltage amplification
VO = 0 to 2 V,
RL = 100
25
°C
0.75
45
D and P
VO = 0 to 2 V,
RL = 100
Full range
0.5
D and P
packages
VO = 0 to 2 V, RL = 100
25
°C
0.5
3
packages
VO = 0 to 2 V, RL = 100
Full range
0.25
Full range is 55°C to 125°C.