TLE206x, TLE206xA, TLE206xB
EXCALIBUR JFET INPUT HIGHOUTPUT DRIVE
POWER OPERATIONAL AMPLIFIERS
SLOS193B FEBRUARY 1997 REVISED MAY 2004
27
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
TLE2062M electrical characteristics at specified free-air temperature, VCC± = ±5 V
PARAMETER
TEST CONDITIONS
TA
TLE2062M
TLE2062AM
TLE2062BM
UNIT
A
MIN
TYP
MAX
TLE2062M
25
°C
1
5
TLE2062M
Full range
7
VIO
Input offset voltage
TLE2062AM
25
°C
0.9
4
mV
VIO
Input offset voltage
TLE2062AM
Full range
6
mV
TLE2062BM
25
°C
0.7
3
TLE2062BM
VIC = 0,
RS = 50
Full range
5
αVIO
Temperature coefficient of input offset voltage
VIC = 0,
RS = 50
Full range
6
V/°C
Input offset voltage long-term drift (see Note 4)
25
°C
0.04
V/mo
IIO
Input offset current
25
°C
1
pA
IIO
Input offset current
Full range
15
nA
IIB
Input bias current
25
°C
3
pA
IIB
Input bias current
Full range
30
nA
VICR
Common-mode input voltage range
25
°C
1.6
to
4
2
to
6
V
VICR
Common-mode input voltage range
Full range
1.6
to
4
V
RL = 10 k
25
°C
3.5
3.7
RL = 10 k
Full range
3
VOM +
Maximum positive peak output
FK and JG
packages
RL = 600
25
°C
2.5
3.6
V
VOM +
Maximum positive peak output
voltage swing
FK and JG
packages
RL = 600
Full range
2
V
voltage swing
D and P
packages
RL = 100
25
°C
2.5
3.1
D and P
packages
RL = 100
Full range
2
RL = 10 k
25
°C
3.5
3.9
RL = 10 k
Full range
3
VOM
Maximum negative peak output
FK and JG
packages
RL = 600
25
°C
2.5
3.5
V
VOM
Maximum negative peak output
voltage swing
FK and JG
packages
RL = 600
Full range
2
V
voltage swing
D and P
packages
RL = 100
25
°C
2.5
2.7
D and P
packages
RL = 100
Full range
2
VO = ± 2.8 V,
RL = 10 k
25
°C
15
80
VO = ± 2.8 V,
RL = 10 k
Full range
2
VO = 0 to 2.5 V,
RL = 600
25
°C
1
65
FK and JG
packages
VO = 0 to 2.5 V,
RL = 600
Full range
0.5
AVD
Large-signal differential voltage
FK and JG
packages
VO = 0 to 2.5 V,
RL = 600
25
°C
1
16
V/mV
AVD
Large-signal differential voltage
amplification
VO = 0 to 2.5 V,
RL = 600
Full range
0.5
V/mV
amplification
VO = 0 to 2 V,
RL = 100
25
°C
0.75
45
D and P
packages
VO = 0 to 2 V,
RL = 100
Full range
0.5
D and P
packages
VO = 0 to 2 V,
RL = 100
25
°C
0.5
3
VO = 0 to 2 V,
RL = 100
Full range
0.25
Full range is 55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25 °C using the Arrhenius equation and assuming an activation energy of 0.96 eV.