Specifications
24
3-phase
400-V AC
models
Model 3G3JV-
A4002
A4004
A4007
A4015
A4022
A4037
Power
supply
Rated voltage and frequency
Allowable voltage fluctuation
Allowable frequency
fluctuation
Input power supply capacity
(kVA) (see note 1)
Heat radiation (W) (see note 2)
Weight (kg)
Cooling method
3-phase 380 to 460 V AC at 50/60 Hz
–
15% to 10%
±
5%
1.3
1.9
3.6
5.1
5.9
9.1
23.1
1.0
Natural cooling
30.1
1.1
54.9
1.5
75.7
1.5
Cooling fan
83.0
1.5
117.9
2.1
Note:
1. The power supply capacity, is the capacity when the Inverter is operating at its rated output. The value will vary with the
impedance at the input power supply side. (Because the power factor of the input power supply changes, the power factor
will improve if an AC reactor is inserted.) The ratio with the rated current of the motor used and the rated output current of
the Inverter will vary.
2. The
“
heat radiation
”
is the power consumed in the Inverter when it is operating at its rated output.
Max. applicable motor capacity (kW)
Output
specifications
0.2
0.4
0.75
1.5
2.2
3.7
Rated output capacity (kW)
Rated output current (A)
Rated output voltage (V)
Max. output frequency
Harmonic-current countermeasures
Control method
Carrier frequency
Frequency control range
Frequency precision (temperature
characteristics)
Frequency setting resolution
0.9
1.2
3-phase 380 to 460 V AC (according to the input voltage)
400 Hz parameter setting
DC reactor (option) connection possible
Sine wave PWM (V/f control)
2.5 to 10.0 kHz (in vector control)
0.1 to 400 Hz
Digital commands:
±
0.01% (
–
10
°
C to 50
°
C)
Analog commands:
±
0.5% (25
°
C
±
10
°
C)
Digital commands: 0.1 Hz (less than 100 Hz) and 1 Hz (100 Hz or over)
Analog commands: 0.06 Hz/60 Hz (equivalent to 1/1000)
0.01 Hz (calculated resolution)
150% of rated output current for 1 min
Selectable with FREQ adjuster: 0 to 10 V DC (20 k
), 4 to 20 mA (250
), and 0 to 20 mA (250
)
0.0 to 999 s (Independent acceleration and deceleration time settings)
Approx. 20%
Set a user V/f pattern
Protection by electronic thermal
Stops at approx. 250% of rated output current
Stops in 1 min at approximately 150% of rated output current
Stops when main-circuit DC voltage is approximately 820 V
Stops when main-circuit DC voltage is approximately 400 V
Stops for 15 ms or more. By setting the Inverter to momentary power interruption mode,
operation can be continued if power is restored within approximately 0.5 s.
Detects at 110
°
C
±
10
°
C
Protection at rated output current level
Lit when the main circuit DC voltage is approximately 50 V or less.
Indoors (with no corrosive gas, oil spray, or metallic dust)
Operating:
–
10
°
C to 50
°
C
Operating: 95% max. (with no condensation)
–
20
°
C to 60
°
C
1,000 m max.
5 M
min. (Do not carry out any insulation resistance or withstand voltage tests)
9.8 m/s
2
max. between 10 to 20 Hz
2.0 m/s
2
max. between 20 and 50 Hz
Panel-mounting models: Conforms to IP20
1.4
1.8
2.6
3.4
3.7
4.8
4.2
5.5
6.6
8.6
Control
characteristics
Output frequency resolution
Overload capacity
External frequency set signal
Acceleration/deceleration time
Braking torque
Voltage/frequency characteristics
Motor protection
Instantaneous overcurrent protection
Overload protection
Overvoltage protection
Undervoltage protection
Momentary power interruption
compensation (selection)
Cooling fin overheating
Grounding protection
Charge indicator (RUN indicator)
Location
Ambient temperature
Ambient humidity
Ambient temperature
Altitude
Insulation resistance
Vibration resistance
Protective
functions
Environment
Degree of protection