E. 4mm Parking Snap: When touched by the operator, this
snap will deactivate the alarm for six seconds. This allows
time for the operator to disconnect the coil cord from the
wrist band and park it on this snap. While parked, the coil
cord disables the alarm, allowing the operator to leave the
workstation. The OPERATOR GROUND LED will remain
off while the cord is parked. Upon returning and removing
the coil cord from the parking snap, the operator has six
seconds to hook up to the wrist band before the alarm
sounds.
F. 24 VAC Power Jack: Connect the power adapter here.
G. Mat Connection: Monitors worksurface mat. NOTE: To
disable worksurface monitoring, shunt this terminal to the
neighboring GND terminal with bus wire.
H. Mat Ground: Grounds worksurface mat.
Installation
Remove the monitor from its packaging and inspect for
any shipping damage. Confirm that the work surface is
1 x 107 ohms or less and has a conductive layer such as
Dual Layer Rubber, Dissipative 3-Layer Vinyl, or Micastat
Dissipative Laminate with conductive buried layers.
1. Locate a nearby power outlet and test it for proper wiring
Analyzer to verify proper wiring and ground.
2. The Multi-Mount Continuous Monitor may be mounted
to a convenient location using the included mounting
screws or Velcro set. See Figure 3 for installation
set-up.
TB-3054 Page 3 of 5
4. Route the black ground cord to the monitor’s green
terminal block labeled MAT.
5. Route the green ground cord to the monitor’s green
terminal block labeled GND.
6. Connect the power adapter to the monitor’s power jack
labeled “24VAC” and the other end to a proper voltage
source.
2014 DESCO INDUSTRIES INC.
Employee Owned
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 (909) 627-8178
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 (781) 821-8370 Website:
Desco.com Figure 3. Installation method #1 of the Multi-Mount
Continuous Monitor
Screw allows ground cord to be
bolted to mat; keeps cord from
disconnecting.
or
10mm snaps need to pierce and clinch
bottom side of mat. Snaps need to be
12 to 72 inches apart
Worksurface Mat
Power Adapter
Connection
Figure 4. Installation method #2 of the Multi-Mount
Continuous Monitor
3. Install Screws and Washers or Push and Clinch snaps 12
to 72 inches apart from each other on the work surface
mat. Make sure that they pierce and clinch the bottom
side of the mat.
Figure 5. Mounting hole locations on the Multi-Mount
Continuous Monitor (all dimensions are in inches)
2X .188"
3.50"
3.87"
.90"
2.08"