12
Analogue power controllers Type ACI
General
Type
ACI 30-1
ACI 50-1
Product description
The versatile ACI analogue power controller is designed for very precise temperature and transformer control.
Due to the built-in micro-computer the controller can operate in phase angle as well as in burst firing control method.
The controller automatically adapts to the load to ensure a smooth inrush, and in burst-firing mode it will further
eliminate the unwanted effects of DC magnetizing on transformers. The ACI unit is easily connected to a
PLC/regulator by means of one of the selectable input signals.
Typical applications
Analogue control of heaters and infrared lamps. The ACI controller is also ideal on transformer controlled processes.
Design standard
IEC/EN 60947-4-3
Approvals
CE
Output specifications
Operational current
AC-1 (heater load)
30 A
50 A
AC-56a (transformer load)
30 A
50 A
Operational voltage
208 - 230 V a.c.
400 - 480 V a.c
Control method
Phase angle control
Selectable linear power or linear voltage
Burst firing control
Selectable cycle time: 0.- 60 seconds
Leakage current max.
1 mA
Minimum operational current
10 mA
Semiconductor protection fusing
type 1 co-ordination
50 A gL/gG
type 2 co-ordination
1800 A
2S
1800 A
2S
Thermal specifications
and environment
Power dissipation,
continuous duty
1.2 W/Amp.
Power dissipation,
intermittent duty
1.2 W/Amp.
× duty cycle
Ambient temperature range
-5 to 40 °C
Cooling method
Natural convection
Mounting
Vertical (see also general mounting instructions)
Max. ambient temperature
with limited current
60 °C, see derating for high temperatures in chart below
Storage temperature range
-20 to 80 °C
Protection degree/pollution
degree
IP 20/3
Insulation specifications
Rated insulation voltage, Ui
660 V
Rated impulse withstand
voltage, Uimp
4 kV
Installation category
III
Control specifications
Control supply voltage
19- 28 V a.c./d.c.
Control signals:
Current loop control
4-20 mA, 20-4 mA, 0-20 mA and 20-0 mA (voltage drop < 3 V)
Voltage control
0-10 V d.c. and 10-0 V d.c. (input resistance > 300 k
)
Potentiometer control
0-10 k
and 10-0 k
Isolation:
Control inputs
Floating control input
Voltage line to control
2.5 kV a.c.
Voltage supply to control
500 V a.c.
Protection
Supply and control inputs are protected against overload and over voltage
EMC immunity
Meets requirements of EN 50082-1 and EN 50082-2
Features
SCR power chip with LTE technology
Compact modular design complete
with heat sink
DIN-rail mountable
Built-in varistor protection
Accepts current loop, voltage and
potentiometer control inputs
Selectable phase angle and burst firing
control method
Micro-computer controlled for
maximum performance
Built-in EMC filter
LED status indicator
IP 20 protection
Problem-free specification according
to industry standard
Easy and quick installation