![](http://datasheet.mmic.net.cn/70000/01K101-270E3_datasheet_2557454/01K101-270E3_2.png)
215
Rosenberger Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com
Series RPC-1.00
R
P
C
-1.
00
Technology
Technical Data Series RPC-1.00
Applicable standards | Anwendbare Standards
Interface according to | Interface gem
IEC 61169-31
Electrical data | Elektrische Daten
Impedance | Wellenwiderstand
50
Ω
Frequency range | Frequenzbereich
DC to 110 GHz
Return loss (cable connector straight) | Rückfludmpfung (Kabelsteckverbinder, gerade)
≥ 23 dB, DC to 50 GHz
≥ 19 dB, 50 GHz to 75 GHz
≥ 14 dB, 75 GHz to 110 GHz
Insertion loss (cable connector straight) | Dmpfung (Kabelsteckverbinder, gerade)
≤ 0.05 dB x f[GHz]
Insulation resistance | Isolationswiderstand
≥ 5 GΩ
Center contact resistance | bergangswiderstand Innenleiter
≤ 4.0 mΩ
Outer contact resistance | bergangswiderstand Auenleiter
≤ 1.0 mΩ
Test voltage | Prüfspannung
500 V rms
Working voltage | Betriebsspannung
150 V rms
RF-leakage | Schirmdmpfung
≥ 90 dB up to 1 GHz
Mechanical data | Mechanische Daten
Mating cycles | Steckzyklen
≥ 500
Center contact captivation | Innenleiter Haltekraft
≥ 10 N
Coupling torque recommended | Anzugsdrehmoment empfohlen
0.3 Nm to 0.41 Nm
Coupling test torque | Prüfdrehmoment
0.70 Nm
Environmental data | Umweltdaten
Temperature range | Temperaturbereich
-40 °C to +85 °C
Thermal shock | Temperaturzyklen
IEC 61169-1, Subclause 9.4.4
Corrosion resistance | Korrosionsbestndigkeit
IEC 61169-1, Subclause 9.4.6
Vibration | Vibration
IEC 61169-1, Subclause 9.3.3
Shock | Schock
IEC 61169-1, Subclause 9.3.14
Moisture resistance | Feuchtigkeitsbestndigkeit
IEC 61169-1, Subclause 9.4.3
Max. soldering temperature | Maximale Lttemperatur
IEC 61760-1, +260 °C for 10 sec.
Materials | Materialien
Center contact | Innenleiter
Beryllium copper, gold-plated
Outer contact | Auenleiter
Beryllium copper, gold-plated
Dielectric | Dielektrikum
PEEK
Rosenberger-connectors fulfill in principle the indicated data of the Technical Data.
Individual values of connectors may deviate depending upon application, design,
type of cable, assembly method and execution. Specific data sheets for particular
products can be provided on request from your Rosenberger sales partner.
Rosenberger-Steckverbinder erfüllen grundstzlich die in den Technischen Daten
angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -aus-
führung knnen einzelne Werte von Steckverbindern hiervon abweichen. Spezifische
Datenbltter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem Rosenber-
ger-Ansprechpartner.