TLC1550I, TLC1550M TLC1551I
10-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH PARALLEL OUTPUTS
SLAS043C – MAY 1991 – REVISED MARCH 1995
2–4
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
DD1
, V
DD2
, and V
DD3
(see Note 1)
Input voltage range, V
I
(any input)
Output voltage range, V
O
Peak input current (any digital input)
Peak total input current (all inputs)
Operating free-air temperature range, T
A
: TLC1550I, TLC1551I
6.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–0.3 V to V
DD
+ 0.3 V
–0.3 V to V
DD
+ 0.3 V
±
10 mA
±
30 mA
–40
°
C to 85
°
C
–55
°
C to 125
°
C
–65
°
C to 150
°
C
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TLC1550M
Storage temperature range, T
stg
Case temperature for 10 seconds: FK or FN package
Lead temperature 1,6 mm (1/16 inch) from the case for 10 seconds: J or NW package
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
260
°
C
260
°
C
. . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: VDD1 is the voltage measured at DGTL VDD1 with respect to DGND1. VDD2 is the voltage measured at DGTL VDD2 with respect to the
DGND2. VDD3 is the voltage measured at ANLG VDD with respect to AGND. For these specifications, all ground terminals are tied
together (and represent 0 V). When VDD1, VDD2, and VDD3 are equal, they are referred to simply as VDD.
recommended operating conditions
MIN
NOM
MAX
UNIT
Supply voltage, VDD1, VDD2, VDD3
Positive reference voltage, Vref+ (see Note 2)
Negative reference voltage, Vref– (see Note 2)
Differential reference voltage, Vref+ – Vref– (see Note 2)
Analog input voltage range
4.75
5
5.5
V
VDD3
V
0
V
0.3
0.3
V
0
VDD3
V
High-level control input voltage, VIH
Low-level control input voltage, VIL
Input clock frequency, f(CLKIN)
Setup time, CS low before WR or RD goes low, tsu(CS)
Hold time, CS low after WR or RD goes high, th(CS)
WR or RD pulse duration, tw(WR)
2
V
0.8
V
0.5
7.8
MHz
0
ns
0
ns
50
ns
Input clock low pulse duration, twL(CLKIN)
40% of
period
80% of
period
Operating free air temperature TA
Operating free-air temperature, TA
TLC155xI
–40
85
°
C
TLC1550M
–55
125
NOTE 2: Analog input voltages greater than that applied to REF+ convert to all 1s (1111111111), while input voltages less than that applied to
REF– convert to all 0s (0000000000). The total unadjusted error may increase as this differential voltage falls below 4.75 V.