absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
Input voltage range, V
I
(see Note 1)
Continuous channel current
Input clamp current, I
IK
(V
I/O
< 0)
Package thermal impedance,
θ
JA
(see Note 2): DB package
–0.5 V to 7 V
–0.5 V to 7 V
128 mA
–50 mA
104
°
C/W
113
°
C/W
139
°
C/W
81
°
C/W
120
°
C/W
–65
°
C to 150
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DBQ package
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DGV package
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DW package
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PW package
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
2. The package thermal impedance is calculated in accordance with JESD 51.
recommended operating conditions (see Note 3)
MIN
MAX
UNIT
VCC
VIH
VIL
TA
NOTE 3: All unused control inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs literature number SCBA004.
Supply voltage
4
5.5
V
High-level control input voltage
2
V
Low-level control input voltage
0.8
V
°
C
Operating free-air temperature
–40
85
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
VIK
II
ICC
ICC§
Ci
Cio(OFF)
VCC = 4.5 V,
VCC = 5.5 V,
VCC = 5.5 V,
VCC = 5.5 V,
VI = 3 V or 0
VO = 3 V or 0,
VCC = 4 V,
TYP at VCC = 4 V
II = –18 mA
VI = 5.5 V or GND
IO = 0,
One input at 3.4 V,
–1.2
±
1
V
μ
A
μ
A
mA
VI = VCC or GND
Other inputs at VCC or GND
3
Control inputs
2.5
Control inputs
4
pF
OE = VCC
4.5
pF
VI = 2.4 V,
II = 15 mA
14
20
ron
VI= 0
VI = 0
II = 64 mA
II = 30 mA
II = 15 mA
5
7
VCC = 4.5 V
5
7
VI = 2.4 V,
10
15
All typical values are at VCC = 5 V (unless otherwise noted), TA = 25
°
C.
§This is the increase in supply current for each input that is at the specified TTL voltage level rather than VCC or GND.
Measured by the voltage drop between the A and B terminals at the indicated current through the switch. On-state resistance is determined by
the lowest voltage of the two (A or B) terminals.