130
Enclosed Switch
SHL
■ General Ratings
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
Micro Voltage/Current Load Model
■ Characteristics (For SHL-W155)
Note: 1. The above figures are for steady-state currents.
2. The above ratings may vary depending on the model. Contact your OMRON representative for further details.
3. The head section of the plunger type SHL-D(Q)
@@ is excluded.
4. Durability values are calculated at an operating temperature of 5
°C to 35°C, and an operating humidity of 40% to 70%. Contact your
OMRON sales representative for more detailed information on other operating environments.
5. The values are for the plunger-type models.
Rated voltage
Non-inductive load
Inductive load
Inrush current
Resistive load
Lamp load
Inductive load
Motor load
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
125 VAC
10 A
1.5 A
3 A
2.5 A
15 A max.
250 VAC
10 A
1.5 A
2 A
1.5 A
480 VAC
2 A
---
8 VDC
10 A
2 A
5 A
2 A
14 VDC
10 A
2 A
5 A
2 A
30 VDC
5 A
1.5 A
125 VDC
0.4 A
0.05 A
250 VDC
0.2 A
0.03 A
Rated voltage
Non-inductive load
Resistive load
NC
NO
125 VAC
0.1 A
8 VDC
0.1 A
14 VDC
0.1 A
30 VDC
0.1 A
Degree of protections (see note 3)
IP67 (EN60947-5-1)
Durability (see note 4)
Mechanical:
10,000,000 operations min.
Electrical:
500,000 operations min.
Operating speed
0.1 mm to 0.5 m/s (hinge lever models)
Operating frequency
Mechanical:
120 operations/min
Electrical:
30 operations/min
Rated frequency
50/60 Hz
Insulation resistance
100 M
min. (at 500 VDC)
Contact resistance
15 m
max. (initial value)
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
2,000 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1) between current-carrying metal part and ground, and
between each terminal and non-current-carrying metal part
Rated insulation voltage (U
i)
150 V (EN60947-5-1)
Switching overvoltage
1,000 VAC max., 300 VDC max. (EN60947-5-1)
Pollution degree (operating environment)
3 (EN60947-5-1)
Short-circuit protective device (SCPD)
10 A fuse type gI or gG (IEC269)
Conditional short-circuit current
100 A (EN60947-5-1)
Conventional enclosed thermal current
(I
the)
5 A (EN60947-5-1)
Protection against electric shock
Class II (grounding not required with double insulation)
OFF reverse voltage
1,000 VAC max., 300 VDC max. (EN60947-5-1)
Vibration resistance
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Destruction:
1,000 m/s2 min.
Malfunction:
300 m/s2 min.
Ambient temperature
Operating:
–10
°C to 80°C (with no icing)
Ambient humidity
Operating:
35% to 95%
Weight (see note 5)
Approx. 62 to 72 g