OP27A, OP27C, OP27E, OP27G
OP37A, OP37C, OP37E, OP37G
LOW-NOISE HIGH-SPEED PRECISION OPERATIONAL AMPLIFIERS
SLOS100B – FEBRUARY 1989 – REVISED AUGUST 1994
2–5
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
POST OFFICE BOX 1443
HOUSTON, TEXAS 77251–1443
recommended operating conditions
MIN
NOM
MAX
UNIT
Supply voltage, VCC+
Supply voltage, VCC –
4
15
22
V
–4
±
11
–15
–22
V
Common mode input voltage VIC
Common-mode input voltage, VIC
VCC
±
=
±
15 V,
VCC
±
=
±
15 V,
TA = 25
°
C
TA = – 55
°
C to 125
°
C
V
±
10.5
–25
Operating free-air temperature, TA
85
°
C
electrical characteristics at specified free-air temperature, V
CC
±
=
±
15 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
T
TA
OP27E, OP37E
MIN
TYP
OP27G, OP37G
MIN
TYP
UNIT
MAX
MAX
100
VIO
Input offset voltage
VO = 0,
RS = 50
, See Note 3
VIC = 0
25
°
C
Full range
10
25
30
μ
V
60
220
α
VIO
Average temperature
coefficient of input
offset voltage
Full range
0.2
0.6
0.4
1.8
μ
V/
°
C
Long-term drift of input
offset voltage
See Note 4
0.2
1
0.4
2
μ
V/mo
IIO
Input offset current
VO= 0
VO = 0,
VIC= 0
VIC = 0
25
°
C
Full range
25
°
C
Full range
7
35
12
75
nA
50
135
±
80
±
150
IIB
Input bias current
VO= 0
VO = 0,
VIC= 0
VIC = 0
±
10
±
40
±
60
±
15
nA
VICR
Common-mode input
voltage range
25
°
C
11
to
–11
11
to
–11
V
Full range
10.3
to
–10.3
±
12
±
10
±
11.5
1000
10.5
to
–10.5
±
11.5
±
10
10.5
RL
≥
2 k
RL
≥
0.6 k
RL
≥
2 k
RL
≥
2 k
,
RL
≥
1 k
,
RL
≥
0.6 k
, VO =
±
1 V,
VCC
±
=
±
4 V
RL
≥
2 k
,
±
13.8
±
11.5
±
13.5
±
11.5
VOM
Peak output voltage swing
V
Full range
VO =
±
10 V
VO =
±
10 V
1800
700
1500
Large signal differential
Large-signal differential
voltage amplification
800
1500
1500
AVD
250
700
200
500
V/mV
VO =
±
10 V
Full range
600
450
ri(CM)
Common-mode input
resistance
3
2
G
ro
Output resistance
VO = 0,
VIC =
±
11 V
VIC =
±
10 V
VCC
±
=
±
4 V to
±
18 V
VCC
±
=
±
4.5 V to
±
18 V
IO = 0
25
°
C
25
°
C
Full range
25
°
C
Full range
70
70
CMRR
Common-mode rejection
ratio
114
126
100
120
dB
110
96
kSVR
Supply voltage rejection
ratio
100
96
120
94
90
118
dB
Full range is – 25
°
C to 85
°
C.
NOTES:
3. Input offset voltage measurements are performed by automatic test equipment approximately 0.5 seconds after applying power.
4. Long-term drift of input offset voltage refers to the average trend line of offset voltage versus time over extended periods after the
first 30 days of operation. Excluding the initial hour of operation, changes in VIO during the first 30 days are typically 2.5
μ
V